Pune
08048046710
+919112455550

'long term online liquid flow measurement'

Items tagged with 'long term online liquid flow measurement'

6814772a5d263414004dd4a4 Card 2

product image
Flow

MS UFM 3111 Flow Meter can be virtually applied to a wide range of long term online measurement. Convertor protection Class IP 67, transducer protection class IP 68. A variety of liquid applications can be accommodated: ultra-pure liquids, portable water, chemicals, raw sewage, reclaimed water, cooling water, river water, plant effluent etc.

6814772a5d263414004dd4a4 Card 2

product image
TDS

Total Dissolved solids, smaller than 2 microns, refer to any minerals, salts, metals, in the form of molecules, atoms, cations or anions dissolved in water. Total dissolved solids (TDS) comprise inorganic salts (principally calcium, magnesium, potassium, sodium, bicarbonates, chlorides and sulfates) and some small amounts of organic matter that dissolve in water. The TDS concentration is the sum of all filterable substances in water that can be determined gravimetrically. However, in most cases, TDS is primarily comprised of ions. TDS is mainly used in the studies of water quality in the natural bodies of water, including surface and ground sources. It is an Microprocessor based online measurement of specific TDS of solution using a TDS cell for R.O plant or D.M plant applications. It enables to measure the TDS without manual balancing and specific TDS is read directly on a digital panel. This is available in panel mounting facility in compact size. Why Measure Total Dissolved Solids? TDS in drinking water can originate from natural sources, urban run-off, municipal and industrial waste, chemicals used in treating water and the actual plumbing infrastructure. While TDS is not considered a primary pollutant, it is an indicator of water quality. The USEPA secondary water quality standard for TDS concentration is 500 mg/L to ensure drinking water palatability. High levels of dissolved solids in drinking water can affect the taste causing it to be bitter or salty. High levels of TDS can also lead to scaling and corrosion in any application but especially in boilers and cooling water.

6814772a5d263414004dd4a4 Card 2

product image
pH

FEATURE • Online Measurement • Auto / Manual Temp Compensation • 4-20 mA DC Output • On-Line Indication through LCD Display • Simple operating interface • 2 Wire System • Easy Installation DESCRIPTION MicroSet pH Indicating Transmitter Model MS pH 211 T is used for various industrial applications. MS pH 211 T is a convenient and cost-effective solution for monitoring and transmitting pH or ORP value. It can accept input from any pH or ORP sensor. MS pH 211 T output is in the form of Analogue 4-20 mA DC two wire

6814772a5d263414004dd4a4 Card 2

product image
pH

FEATURE • On-line measurement. 2 wire system. • 4-20 mA DC output. Auto/Manual temperature compensation. • On-Line indication through LCD display. • Simple operating interface with basic pictographs. • Easy installation with pre assembled empty enclosure & Plug in terminals. • Protection Class IP-66 • Software calibration with buffer solution MicroSet series MS pH 211T FLP are PH / ORP transmitters used for various industrial applications. It can accept input from pH / ORP electrode & pH / ORP signal is transmitted in the form of electrical 4 - 20 mA signal. The on-line pH / ORP indication is provided through LCD. Span / Zero adjustments are easily accessibly. These transmitters are suitable for any make of electrode.

6814772a5d263414004dd4a4 Card 2

product image
pH

FEATURE • Sterilizable / Autoclavable • Gel electrolyte • Sterilization Temperature up to 130°C • 35 Steam Cycles - Ensures fast & accurate long life in actual process conditions • Fast, Accurate, Improved Stability, Reliable • 120, 170, 220, 270 and 320 mm Length available • Compatible with any make pH Transmitter DESCRIPTION Designed for accuracy and stability in a heat intensive application, the new MS pH 04 Ferm series pH sensors are optimized for autoclaving and steam sterilization in biotechnology applications. MS pH 04 sensors exhibit unparalleled stability after exposure to high temperature sterilization. The reference electrode uses a silver silver chloride sensor in combination with a new gelled potassium chloride electrolyte to provide a stable reference potential through the single ceramic reference junction. PRINCIPLE Why is pH Measurement required ? To check the acidic or alkaline nature of aqueous solution. pH (Potential Hydrogen) is unit of measurement, used to determine the Acidity or Alkalinity of an aqueous solution. Practical pH scale for industrial instrumentation ranges from 0 to 14 pH. The acidic substances range from 0 to 6 and on the other end are the alkaline substances, which range from 8 to 14, with pH 7 being neutral, this is the pH of pure water which is neither very acidic nor very alkaline, is said to be neutral. How is pH measured ? Although everyone is familiar with Litmus paper, the only reliable way to measure pH is using Potentiometric Combination electrodes. These electrodes develop a millivolts output corresponding to pH value of solution which is directly proportional to the Free Hydrogen ion concentration in an aqueous Solution. These generated raw mill volts are fed to MS pH 04 Ferm where it is processed by amplifier & reading is displayed on meter TECHNICAL SPECIFICATION pH Range : 0 ~ 14 pH Body : Glass Temperature Range : 0 to 130°C Operating Pressure : 6 Bar Electrolyte : Gel Reference Junction : Single Ceramic Junction Sterilization temperature : 130°C Shaft Length below Threads : 120 mm (Other Lengths on request at Extra Cost) Shaft Diameter : 12 mm Electrical Connection : S8 Process Connection : PG 13.5

6814772a5d263414004dd4a4 Card 2

product image
pH

FEATURE • Annular PTFE Junction → Fast Response • Due to increased porosity, Increased Sensor Life • Suitable for Viscous, Slurry Application • Easy cleaning • Filled with Gel → Helps to maintain • Zero potential for longer time • Industrial Grade Rugged Construction • Ryton Body (Acid Alkali Resistant) • Easy Installation DESCRIPTION MicroSet make pH Sensor model MS pH 36 is designed for various Industrial Applications. Annular PTFE junction reference aids in the sensor's resistance to harsh environments and helps prolong sensor life. The robust sensor design makes the MS pH 36 reliable in a wide range of aqueous solutions found in pipelines, open tanks or ponds. TECHNICAL SPECIFICATION Range : 0 to 14 pH Body : Ryton Type : Combination Reference Junction : TEFLON Membrane Shape : Rugged Electrode Tip with Semi dome Shape Electrolyte : Combination of HGEL +CEP + Polymer Gel Sensor Output : mV (± 59.4 mV/ORP change at 25°C) Response Time : 95% in 1 second Pressure : 100 PSIG Temperature : 0 ~ 105°C Temperature Compensation : Pt 100 Built-in Measurement Tip : Glass Junction : Double Junction Process Connection : ¾” NPT Male on both Front End and Rear End Mounting : Pipeline (Inline) or Immersion (Tank) or Flow Through Chamber

6814772a5d263414004dd4a4 Card 2

product image
Conductivity

It is an economical meter for online measurement of specific Conductivity of solution using a Conductivity cell for RO plant or DM plant applications. It enables to measure the Conductivity without manual balancing and specific Conductivity is read directly on a digital panel. This is available in panel mounting facility in compact size. PRINCIPLE Conductivity is the ability of a solution, a metal or a gas - in brief all materials to pass an electric current. In solutions the current is carried by cations and anions whereas in metals it is carried by electrons. How well a solution conducts electricity depends on a number of factors: • Concentration of ions • Mobility of ions • Valence of ions • Temperature All substances possess some degree of conductivity. In aqueous solutions the level of ionic strength varies from the low conductivity of ultrapure water to the high conductivity of concentrated chemical samples. Conductivity may be measured by applying an alternating electrical current (I) to two electrodes immersed in a solution and measuring the resulting voltage (U). During this process, the cations migrate to the negative electrode, the anions to the positive electrode and the solution acts as an electrical conductor.

6814772a5d263414004dd4a4 Card 2

product image
Conductivity

It is an economical meter for online measurement of specific Conductivity of solution using a Conductivity cell for R.O plant or D.M plant applications. It enables to measure the Conductivity without manual balancing and specific Conductivity is read directly on a digital panel. This is available in panel mounting facility in compact size.

6814772a5d263414004dd4a4 Card 2

product image
COD BOD

MicroSet launched the new generation COD BOD TSS TOC Sensor which is used for environmental protection purpose. Sensor is reagent free, pollution-free, more economic & robust. Due to small size, it is easier for installation for online continuous water quality monitoring. Sensor comes with Automatic compensation for turbidity interference, with automatic cleaning facility. For long-term monitoring it has excellent stability. Thanks to our R&D team for developing robust, trouble-free controller for processing the signals coming from the sensor. The Controller gives output of RS 485 MODBUS for real time data monitoring demands of SPCB & CPCB.

Still searching for
long term online liquid flow measurement?