Pune
08048033051
+919112455550

conductivity

product image
Conductivity

Conductivity of water allows measuring ionic constituents of all types of water including surface water, process water in water supply and treatment plants. Conductivity is the ability of a solution, a metal or a gas - in brief all materials to pass an electric current. In solutions the current is carried by cations and anions whereas in metals it is carried by electrons. How well a solution conducts electricity depends on a number of factors • Concentration of ions • Mobility of ions • Valence of ions • Temperature All substances possess some degree of conductivity. In aqueous solutions the level of ionic strength varies from the low conductivity of ultrapure water to the high conductivity of concentrated chemical samples. Conductivity may be measured by applying an alternating electrical current (I) to two electrodes immersed in a solution and measuring the resulting voltage (U). During this process, the cations migrate to the negative Electrode, the anions to the positive electrode and the solution acts as an electrical conductor. FEATURE • Advanced Embedded Microcontroller Based Design • Multivariable Display for Process Value, Relay Status, Temperature & 4 to 20 mA output • Easy front key five Point calibration • Auto / Manual Temperature Compensation • Password can be set • LCD display with Backlit • Panel / Field / Wall Mounting • 4 to 20 mA DC and RS 485 Modbus Output • Weatherproof IP 65 protection TECHNICAL SPECIFICATION • Principle : Two Electrode & Four Electrode • Display Range: Conductivity : 0.00 to 500 mS/cm Resistivity : 0.00Ω.cm to 18.00MΩ.cm TDS : 0.00 to 250 g/L Salinity : 700 ppt Temp : -10 to 150°C • Resolution : Conductivity: 0.01µS/cm; 0.01mS/cm • • Resistivity: 0.01MΩ.cm TDS: 0.01mg/L • Salinity : 0.01 ppt Temp: 0.1°C • Accuracy : Conductivity: ±0.5%F.S; Temp: ±0.3°C • Stability : <2%F.S • Temp Compensation : Automatic or manual (NTC 2.25KΩ, NTC 10KΩ, Pt100, Pt 1000) • Relay Output : Two SPST relays, 3A 250VAC, 3A 30VDC • Communication : RS 485 MODBUS RTU • Signal Output : 0/4 to 20mA current • Configuration : Power failure protection, indefinite retention of Parameters • Display : 128 x 64 3.2-inch large graphic dot matrix LCD • Protection Grade : IP65 • Enclosure Material : Enhanced ABS • Dimension : 98 x 98 x 130mm (Panel Cutout size 92x92mm) • Work Temperature : 0 to 60°C, RH<95%, non-condensing • Storage Temperature : -10 to 60°C, RH<55%, non-condensing • Electrical Interface : Reserve three M12 x 1.5 gland • Mounting : Panel & Field (both accessories included) • Power Supply : 85 to 265VAC,9 to 36VDC(Optional) • Weight : 0.6 kg • Power Consumption : < 3W APPLICATION • Water Treatment Plant (WTP) • Wastewater Treatment Plant (WWTP) • Effluent Treatment Plant (ETP) • Sewage Treatment Plant (STP) • RO Water Plant • Power Plant • Hydroponics • Chemical Industry • Textile Industry • Paper & Pulp • Beverages / Food Industry • Pharma Industry • Scrubber Application • Pigment Industry • Steel Industry • Aqua Culture Calibration MS CT 9 & MS CD 999 : https://youtu.be/jizXNx84UXc

product image
Conductivity

Conductivity of water allows measuring ionic constituents of all types of water including surface water, process water in water supply and treatment plants. PRINCIPLE Conductivity is the ability of a solution, a metal, or a gas - in brief all materials to pass an electric current. In solutions the current is carried by cations and anions whereas in metals it is carried by electrons. How well a solution conducts electricity depends on a number of factors : • Concentration of ions • Mobility of ions • Valence of ions • Temperature All substances possess some degree of conductivity. In aqueous solutions, the level of ionic strength varies from the low conductivity of ultrapure water to the high conductivity of concentrated chemical samples. Conductivity may be measured by applying an alternating electrical current (I) to two Electrodes immersed in a solution and measuring the resulting voltage (U). During this process, the cations migrate to the negative Electrode, the anions to the positive electrode and the solution acts as an electrical conductor. FEATURE • Microcontroller Based Design • Auto Ranging • Conductivity or TDS Indication selection by key • Easy Front Key Calibration • Setpoint with decimal point selection • LED Display TECHNICAL SPECIFICATION Conductivity TDS Indicating Controller • Range (Auto Ranging) : Conductivity : 0-20.00 μS/cm, 200.0 μS/cm, 2000 μS/cm TDS : 0-10.00 ppm, 100.0 ppm, 2000 ppm (With 0.50 parameter Selected by Keypad) • Resolution : 0.01, 0.1, 1 for both Conductivity & TDS • Accuracy : ± 1% of Full Scale • Display : 4 Digits Red LED Display • Calibration (for Cond. only : Single Point Manual Calibration • Calibration Slope : ± 30% of Display Reading • TDS Factor : Factory Def. 0.49 • Relay O/P : 1 No, (2 Amp / 230 VAC Rating) • Power Requirement : 230 V AC ±10%, 50Hz Single Phase • Environment : 5 to 50°C • Dimension : 96 x 96 x 65mm (Grey ABS Cabinet) • Weight : 400 grams for Inst only (Approx) With Conductivity TDS Sensor • MOC of Sensor Body : Derlin • MOC of Electrode : SS 316 • Operating Temp. : 60°C Max • Operating Pressure : 2.5 Bar • Process Connection : ½” BSPM and ¾” BSPM • Cable : Integral 4 Meter • Flow Cell (Optional) : MOC: PVC • Connection for Inlet/Outlet : ¼” BSPF, Sensor : ½” BSPF APPLICATION • Water Treatment Plant (WTP) • Wastewater Treatment Plant (WWTP) • Effluent Treatment Plant (ETP) • Sewage Treatment Plant (STP) • RO Water Plant • Power Plant • Hydroponics • Chemical Industry • Textile Industry • Paper & Pulp • Beverages / Food Industry • Pharma Industry • Scrubber Application • Pigment Industry • Steel Industry • Aqua Culture Product Video of MS CD TDS 18 : https://youtu.be/qew6twzjCW0

product image
Conductivity

MicroSet’s Conductivity Sensors are designed for fast, easy & trouble free start up. These are ideal for measuring the concentration of dissolved solids in water. They are provided with an accurate predetermined factory calibration constant. Rugged design & corrosion resistant material keep electrode spacing & surface area constant. So cell constant remains stable for long period. Durability of material & high resistance to corrosion ensures the long life & require low maintenance. FEATURE • Measure concentration of dissolved solids in water • Accuracy @ 2% FS • Available with 1 / 0.1 / 0.01 cell constants • Temperature compensation through Pt 100 sensor • Flow through assembly in SS 316 (Optional Hastelloy C) TECHNICAL SPECIFICATION • Application : CIP, SIP, WFI and other chemicals • Cell Constant K : 1 / 0.1 / 0.01 (Specify) • Range : 0 to 100 μS/cm for cell constant 0.01 0 to 1000 μS/cm for cell constant 0.1 0 to 10000 μS/cm for cell constant 1 • Accuracy : ± 2% FS • Temperature Compensation : Pt 100 Class A • Temperature Range : 0 to 150°C • Maximum Pressure : 10 kg/cm2 • Material of Construction : SS 316 (Optional Hastelloy C) • Insulator : PTFE ( TEFLON ) • Process Connections : ¾” NPT Threaded at Front end & Cable end (1” Tri-clover Optional) • Insertion Length : 50 mm for cell constant 0.01 27.5 mm for cell constant 0.1 28 mm for cell constant 1 • Mounting : Pipeline , immersion & Flow Through Chamber • Standard Cable Length : Integral 5 Meter • Weight : 0.5 kg APPLICATION • Water Treatment Plant (WTP) • Wastewater Treatment Plant (WWTP) • Effluent Treatment Plant (ETP) • Sewage Treatment Plant (STP) • RO Water Plant • Power Plant • Hydroponics • Chemical Industry • Textile Industry • Paper & Pulp • Beverages / Food Industry • Pharma Industry • Scrubber Application • Pigment Industry • Steel Industry • Aqua Culture Product Video of MS CD 999 : https://youtu.be/g4uIyO1N_d8

product image
Conductivity

It is an economical meter for online measurement of specific Conductivity of solution using a Conductivity cell for RO plant or DM plant applications. It enables to measure the Conductivity without manual balancing and specific Conductivity is read directly on a digital panel. This is available in panel mounting facility in compact size. FEATURE • Advanced Embedded Microcontroller Based Design • Panel Mounting • Easy Front Key Calibration • LED Display • 4 to 20 mA DC Isolated Output PRINCIPLE Conductivity is the ability of a solution, a metal or a gas - in brief all materials to pass an electric current. In solutions the current is carried by cations and anions whereas in metals it is carried by electrons. How well a solution conducts electricity depends on a number of factors: • Concentration of ions • Mobility of ions • Valence of ions • Temperature All substances possess some degree of conductivity. In aqueous solutions the level of ionic strength varies from the low conductivity of ultrapure water to the high conductivity of concentrated chemical samples. Conductivity may be measured by applying an alternating electrical current (I) to two electrodes immersed in a solution and measuring the resulting voltage (U). During this process, the cations migrate to the negative electrode, the anions to the positive electrode and the solution acts as an electrical conductor. TECHNICAL SPECIFICATION • Range : 0.00~19.99 µS/cm, 0.0~199.9 µS/cm,0~1999 µS/cm, 0~9999 µS/cm or 0.00~20.00 mS/cm (Specify) • Resolution : 0.01 µS/cm, 0.1 µS/cm, 1 µS/cm , 0.01 mS/cm • Measuring Accuracy : ±1% FS • Indication : 3.5 digit LED display • Retransmission Output : 4 to 20 mA Isolated • Power Requirement : 230 V AC ±10%, 50 Hz Single Phase • Size : 96 x 96 mm • Environment : 0 ~ 50ºC APPLICATION • Water Treatment Plant (WTP) • Wastewater Treatment Plant (WWTP) • Effluent Treatment Plant (ETP) • Sewage Treatment Plant (STP) • RO Water Plant • Power Plant • Hydroponics • Chemical Industry • Textile Industry • Paper & Pulp • Beverages / Food Industry • Pharma Industry • Scrubber Application • Pigment Industry • Steel Industry • Aqua Culture

product image
Conductivity

It is an economical meter for online measurement of specific Conductivity of solution using a Conductivity cell for R.O plant or D.M plant applications. It enables to measure the Conductivity without manual balancing and specific Conductivity is read directly on a digital panel. This is available in panel mounting facility in compact size. FEATURE • Advanced Embedded Microcontroller Based Design • Panel Mounting • Easy Front Key Calibration • LED Display • 4 to 20 mA DC Isolated Output • RS 485 Isolated Output (Optional) TECHNICAL SPECIFICATION • Range : 20.00μS/cm, 200.0μS/cm, 2000μS/cms, 20.00mS/cm, 200.0mS/cm (Specify while ordering ) • Resolution : 0.01μS/cm,0.1μS/cm,1μS/cm, 0.01mS/cm, 0.1mS/cm • Accuracy : ± 1% of F.S • Display : 4 digit Dual red LED Display (Upper Display for Cond. & Lower for Set . Value) • Calibration : Single point manual Calibration • Calibration Slope : ± 30% of Display Reading • Cell Constant : 1.0 Cell constant, ± 10% with ½ ” BSP threading • Current O/P : 4-20mA D.C, Fully Isolated • Relay O/P : Two Relay O/P (potential free Contact of 5 Amp Max.) • Control Setting : Two Set Point with High & Low Value Setting • Environment : 5 to 50°C. • Power Requirement : 230V A.C +/-10%, 50Hz single phase • Dimension & Weight : 96 x 96 x 65 mm (Grey ABS Cabinet), 400grams for Inst. Only (Approx.) APPLICATION • Water Treatment Plant (WTP) • Wastewater Treatment Plant (WWTP) • Effluent Treatment Plant (ETP) • Sewage Treatment Plant (STP) • RO Water Plant • Power Plant • Hydroponics • Chemical Industry • Textile Industry • Paper & Pulp • Beverages / Food Industry • Pharma Industry • Scrubber Application • Pigment Industry • Steel Industry • Aqua Culture

product image
Conductivity

Conductivity of water allows measuring ionic constituents of all types of water including surface waters, process waters in water supply and treatment plants. PRINCIPLE Conductivity is the ability of a solution, a metal or a gas - in brief all materials to pass an electric current. In solutions the current is carried by cations and anions whereas in metals it is carried by electrons. How well a solution conducts electricity depends on a number of factors • Concentration of ions • Mobility of ions • Valence of ions • Temperature All substances possess some degree of conductivity. In aqueous solutions the level of ionic strength varies from the low conductivity of ultrapure water to the high conductivity of concentrated chemical samples. Conductivity may be measured by applying an alternating electrical current (I) to two electrodes immersed in a solution and measuring the resulting voltage (U). During this process, the cations migrate to the negative Electrode, the anions to the positive electrode and the solution acts as an electrical conductor. FEATURE • Advanced Embedded Microcontroller Based Design • Multivariable Display for Process Value, Relay Status, Temperature & 4 to 20 mA output • Easy front key five Point calibration • Auto / Manual Temperature Compensation • IP66 protection grade • Password can be set • 3.2 inch LCD display • Set Point – 4 Nos • 2 x 4 to 20 mA DC Isolated output • Weatherproof IP 66 protection TECHNICAL SPECIFICATION • Principle : Two electrode • Display Range: Conductivity : 0.00~20.00 mS/cm Resistivity : 0.00Ω.cm~18.00MΩ.cm TDS : 0.00~10g/L Salinity : 15ppt Temp : -10~150℃ • Resolution : EC: 0.001μS /cm Resistivity: 0.01MΩ.cm TDS: 0.01mg/L Salinity: 0.01% Temp: 0.1℃ • Accuracy : EC: ±1% FS Temp: 0.5℃ • Repeatability : ±0.3% FS • Temp Compensation : Automatic or manual (Pt100) • Relay Output : Two SPST relays, maximum load 3A/250VAC Set high/low alarm, temperature and wash control • Communication : N/A • Signal Output : Two 0/4~20mA current, Max. Load 1000Ω • Configuration : Power failure protection, indefinite retention of Parameters • Display : 128*64 3.2-inch large graphic dot matrix LCD • Protection Grade : IP66 • Enclosure Material : Enhanced ABS • Dimension : 100 x 100 x 120mm (Panel Cutout size 92x92mm) • Work Temperature : 0~60℃, RH<95%, non-condensing • Storage Temperature : -20~70℃, RH<55%, non-condensing • Electrical Interface : Reserve three M12*1.5 gland • Installation Method : Panel • Power Supply : 100~240 VAC 50/60Hz • Weight : 0.45 kg • Power Consumption : 3W APPLICATION • Water Treatment Plant (WTP) • Wastewater Treatment Plant (WWTP) • Effluent Treatment Plant (ETP) • Sewage Treatment Plant (STP) • RO Water Plant Power Plant • Hydroponics Chemical Industry • Textile Industry Paper & Pulp • Beverages / Food Industry Pharma Industry • Scrubber Application Pigment Industry • Steel Industry Aqua Culture Calibration MS CT 9. & MS CD 999 : https://youtu.be/8Si0jFeL9TQ

Subcategory Tags

Phone Number

08048033051

Please keep 0 before dialling the number.

Email Address team@microsetindia.com

Mon-Thu: 10 AM - 2 PM • Fri: 3 PM - 7AM

Other Website Visit our other website
Address 102, Chinmay, 1103A 10, Lakaki Road, Model Colony, Shivajinagar

Pune, India, 411016