Description

MS UFM 3111 Flow Meter can be virtually applied to a wide range of long term online measurement. Convertor protection Class IP 67, transducer protection class IP 68. A variety of liquid applications can be accommodated: ultra-pure liquids, portable water, chemicals, raw sewage, reclaimed water, cooling water, river water, plant effluent etc. An Ultrasonic Flow Meter measures the velocity of a fluid with ultrasound to calculate volume flow. Using ultrasonic transducers, the flow meter can measure the average velocity along the path of an emitted beam of ultrasound, by averaging the difference in measured transit time between the pulses of ultrasound propagating into and against the direction of the flow or by measuring the frequency shift from the Doppler Effect. Ultrasonic Flow Meters are affected by the acoustic properties of the fluid and can be impacted by temperature, density, viscosity and suspended particulates depending on the exact flow meter FEATURE • Measurement Accuracy 1% • Convertor protection Class IP 67, transducer Protection class IP 68 • Wide measurement range, pipe size from DN 15 mm to DN 6000 mm • Three types installation method : Wall mounted, Din Rail Mounted, Explosion proof box mounted • Connect the temperature transducer can finish the Heat /energy measurement TECHNICAL SPECIFICATION • Principle : Transit-time Ultrasonic Flow Meter • Accuracy : ± 1% • Display : 2 x 20 Characters LCD Back Light • Signal output : 1 way, 4 -20 mA output, electrical resistance 1K, Resistance 0 ~1K, accuracy 0.1% 1 way, OCT pulse Output (Pulse width ~1000 Ms Default is 200 mS 1 Way, Relay output • Signal Input : 3 way, 4 to 20 mA input, Accuracy 0.1% Acquisition Signal such as Temp. Pressure & Liquid Level • DATA Interface : RS 485 Modbus Pipe Installation Condition • Pipe Material : Steel, Stainless Steel, Cast Iron, Copper, Cement pipe, PVC, Aluminum, Glass Steel Product, Linear is allowed • Pipe Diameter : 20~2000mm • Straight Pipe : Transducer Installation should be satisfied upstream 10D Down steam 5D & 30 D from the pump. • Liquide Type : Single Liquid can transmit sound wave such as water (Hot water, Chilled water, city water, sea water, waste Water etc.) • Sewage with small particle content : oil (Crude Oil, lubricating oil, diesel oil, fuel oil, etc.) Chemical (alcohol etc.), plant effluent, Beverages, Ultrapure liquids etc. • Temperature : -30~160°C • Turbidity : No more than 10000ppm and less bubble • Flowrate : 0 to ± 7 m/s Working Environment: • Temperature : Convertor: -20~60°C: Flow Transducer: -30~60°C Humidity: • Convertor : 85%RH • Flow Transducer : can measure under water, water depth≤2 m (Transducers sealed with glue) • Power Supply : DC 8 to 36 V or AC 85 to 264 (Optional) • Power Consumption : 1.5W • Dimension : 132 x 150 x 85 mm • Enclosure Protection Class : IP 67

Keywords

Other Products

view all
product image
Conductivity

Conductivity of water allows measuring ionic constituents of all types of water including surface water, process water in water supply and treatment plants. Conductivity is the ability of a solution, a metal or a gas - in brief all materials to pass an electric current. In solutions the current is carried by cations and anions whereas in metals it is carried by electrons. How well a solution conducts electricity depends on a number of factors • Concentration of ions • Mobility of ions • Valence of ions • Temperature All substances possess some degree of conductivity. In aqueous solutions the level of ionic strength varies from the low conductivity of ultrapure water to the high conductivity of concentrated chemical samples. Conductivity may be measured by applying an alternating electrical current (I) to two electrodes immersed in a solution and measuring the resulting voltage (U). During this process, the cations migrate to the negative Electrode, the anions to the positive electrode and the solution acts as an electrical conductor. FEATURE • Advanced Embedded Microcontroller Based Design • Multivariable Display for Process Value, Relay Status, Temperature & 4 to 20 mA output • Easy front key five Point calibration • Auto / Manual Temperature Compensation • Password can be set • LCD display with Backlit • Panel / Field / Wall Mounting • 4 to 20 mA DC and RS 485 Modbus Output • Weatherproof IP 65 protection TECHNICAL SPECIFICATION • Principle : Two Electrode & Four Electrode • Display Range: Conductivity : 0.00 to 500 mS/cm Resistivity : 0.00Ω.cm to 18.00MΩ.cm TDS : 0.00 to 250 g/L Salinity : 700 ppt Temp : -10 to 150°C • Resolution : Conductivity: 0.01µS/cm; 0.01mS/cm • • Resistivity: 0.01MΩ.cm TDS: 0.01mg/L • Salinity : 0.01 ppt Temp: 0.1°C • Accuracy : Conductivity: ±0.5%F.S; Temp: ±0.3°C • Stability : <2%F.S • Temp Compensation : Automatic or manual (NTC 2.25KΩ, NTC 10KΩ, Pt100, Pt 1000) • Relay Output : Two SPST relays, 3A 250VAC, 3A 30VDC • Communication : RS 485 MODBUS RTU • Signal Output : 0/4 to 20mA current • Configuration : Power failure protection, indefinite retention of Parameters • Display : 128 x 64 3.2-inch large graphic dot matrix LCD • Protection Grade : IP65 • Enclosure Material : Enhanced ABS • Dimension : 98 x 98 x 130mm (Panel Cutout size 92x92mm) • Work Temperature : 0 to 60°C, RH<95%, non-condensing • Storage Temperature : -10 to 60°C, RH<55%, non-condensing • Electrical Interface : Reserve three M12 x 1.5 gland • Mounting : Panel & Field (both accessories included) • Power Supply : 85 to 265VAC,9 to 36VDC(Optional) • Weight : 0.6 kg • Power Consumption : < 3W APPLICATION • Water Treatment Plant (WTP) • Wastewater Treatment Plant (WWTP) • Effluent Treatment Plant (ETP) • Sewage Treatment Plant (STP) • RO Water Plant • Power Plant • Hydroponics • Chemical Industry • Textile Industry • Paper & Pulp • Beverages / Food Industry • Pharma Industry • Scrubber Application • Pigment Industry • Steel Industry • Aqua Culture Calibration MS CT 9 & MS CD 999 : https://youtu.be/jizXNx84UXc

product image
pH

MicroSet pH Indicating Controller Transmitter Model MS pH 97 is used for various industrial applications. MS pH 97 is a convenient and cost-effective solution for monitoring and maintaining pH value. It can accept input from any pH sensor. MS pH 97 output is in the form of Analogue 4-20 mA DC or MODBUS RS 485 RTU (Optional). Online pH indication provided through LED is easily readable. 2 Nos Relay Outputs are provided to operate Alarm, Solenoid Valve, Pump etc. 4 Nos Setpoints for Relays can be programmed using Frontal Keypad. FEATURE • Advanced Embedded Microcontroller Based Design • Touch Keys • Can be connected to pH or ORP • Multivariable Display for Process Value, Relay Status, Temperature & 4 to 20 mA output • Easy Front Key Calibration • Auto / Manual Temperature Compensation • Set Point – 4 Nos • 3.2-inch LCD display • 4 to 20 mA DC Isolated Output for pH or ORP • Password can be Set • Flameproof, Weatherproof IP 66 Protection TECHNICAL SPECIFICATION • pH Range : 0 - 14 pH • ORP Range : ± 2000 mV • Temperature Range : -10 to 150°C • pH Resolution : 0.01 pH • ORP Resolution : 1 mV • Temperature Resolution : 0.1°C • pH Accuracy : 0.1% FS or ± 0.01pH • ORP Accuracy : ± 2 mV • Stability : 0.05% of measuring range every 24 hours without accumulation pH • Repeatability : Better than 0.1% of measuring range • Display : 128 x 64, 3.2-inch graphic dot matrix LCD • Set Point : 4 Nos • Calibration : pH - 3 Point, ORP - 2 Point • Output : Two SPST relays, Load 3A/250VAC, set high/low alarm, temp or clean control • Retransmission Output : Isolated 4-20 mA DC for pH/ORP Max. load 1000 Ohm. • Temp Compensation : Auto (PT-100), Manual (Adjustable 0 to 150°C) • Power Supply : 100 to 240V 50/60Hz • Protection : Weatherproof IP 66 • Work Temperature : 0 to 60°C, RH<95%, non condensing • Storage Temperature : -20 to 70°C, RH<55%,non-condensing • Electrical Interface : ¾” ET • MOC of Enclosure : Aluminium Die Cast • Protection : Flameproof Ex d IIb T6 Gb IP 66 (Ex tb/tc IIIB T85 C Db/Dc) -CMRI Certified • Mounting : Field / Wall Mounted • Power Consumption : 3W APPLICATION • Water Treatment Plant (WTP) • Wastewater Treatment Plant (WWTP) • Effluent Treatment Plant (ETP) • Sewage Treatment Plant (STP) • RO Water Plant • Power Plant • Hydroponics • Chemical Industry • Textile Industry • Paper & Pulp • Beverages / Food Industry • Pharma Industry • Scrubber Application • Pigment Industry • Steel Industry • Aqua Culture Calibration MS pH 97 FLP & MS pH 36 : https://youtu.be/c0kpYwri6w4

product image
pH

MicroSet pH ORP Indicating Controller Transmitter Model MS pH 97 is used for various industrial applications. MS pH 97 is a convenient and cost-effective solution for monitoring and maintaining pH or ORP value. It can accept input from any pH or ORP sensor. MS pH 97 output is in the form of Analogue 4-20 mA DC or MODBUS RS 485 RTU (Optional). Online pH ORP indication provided through LCD display is easily readable. 2 Nos Relay Outputs are provided to operate Alarm, Solenoid Valve, Pump etc. 4 Nos Setpoints for Relays can be programmed using Frontal Keypad FEATURE • Advanced Embedded Microcontroller Based Design • Can be connected to pH or ORP electrodes • Multivariable Display for Process Value, Relay Status, Temperature & 4 to 20 mA output • Easy Front Key Calibration • Auto / Manual Temperature Compensation • Set Point – 4 Nos • 3.2-inch LCD display • 4 to 20 mA DC Isolated Output for pH or ORP • Password can be Set • Weatherproof IP 66 Protection TECHNICAL SPECIFICATION • pH Range : 0 - 14 pH • ORP Range : ± 2000 mV • Temperature Range : -10 to 150°C • pH Resolution : 0.01 pH • ORP Resolution : 1 mV • Temperature Resolution : 0.1°C • pH Accuracy : 0.1% FS or ± 0.01pH • ORP Accuracy : ± 2 mV • Stability : 0.05% of measuring range every 24 hours without accumulation pH • Repeatability : Better than 0.1% of measuring range • Display : 128*64, 3.2-inch graphic dot matrix LCD • Set Point : 4 Nos • Calibration : pH - 3 Point, ORP - 2 Point • Output : Two SPST relays, Max. load 3A/250VAC, set high/low alarm, temp or clean control • Retransmission Output : Isolated 4-20 mA DC for pH/ORP Max. load 1000Ω ( RS 485 Optional) • Temperature Compensation : Auto (PT-100), Manual (Adjustable 0 to 150°C) • Power Supply : 100~240V 50/60Hz • Enclosure MOC : ABS • Protection : Weatherproof IP 66 • Work Temperature : 0~60℃, RH<95%, non-condensing • Storage Temperature : -20~70℃, RH<55%, non-condensing • Mounting : Panel Mounted • Electrical Interface : Reserve three M12*1.5 gland • Dimensions : 100 x 100 x120mm (Panel Cutout size 92X92mm) • Weight : 0.45 kg • Power Consumption : 3W APPLICATION • Water Treatment Plant (WTP) • Wastewater Treatment Plant (WWTP) • Effluent Treatment Plant (ETP) • Sewage Treatment Plant (STP) • RO Water Plant • Power Plant • Hydroponics • Chemical Industry • Textile Industry • Paper & Pulp • Beverages / Food Industry • Pharma Industry • Scrubber Application • Pigment Industry • Steel Industry • Aqua Culture Calibration Video of MS pH 97 & MS pH 02 : https://youtu.be/12sG9OD3KKE