Pune
08048046710
+919112455550

Products

6814772a5d263414004dd4a4 Card 2

product image
Dissolved Oxygen

MicroSet Dissolved Oxygen Indicating Controller Transmitter Model MS DO 27 is used for various industrial applications such as ETP, STP, WTP, Package drinking water, Power plant. MS DO 27 is a convenient and cost effective solution for monitoring and maintaining DO value. MS DO 27 accept input from any DO sensor in the form of milli Volts. MS DO 97 output is in the form of Analogue 4-20 mA DC or MODBUS RS 485 RTU (Optional). Online DO indication provided through 1” bright large LED which is easily readable, 2 Nos Relay Outputs are provided to operate Alarm, Solenoid Valve, Pump etc.4 Nos Setpoints for Relays can be programmed using Frontal Keypad.

6814772a5d263414004dd4a4 Card 2

product image
Dissolved Ozone

Online Dissolved Ozone Meter is used for continuous monitoring and controlling of ozone value in water treatment plants, canning plants, drinking water distribution networks, swimming pools, cooling and circulating water, water treatment projects, etc.

6814772a5d263414004dd4a4 Card 2

product image
Dissolved Chlorine

Online Residual Dissolved Chlorine controller is widely used for the continuous monitoring and controlling of residual chlorine value in water solution, such as the automatic control of recirculating water, chlorination control in swimming pool, distribution network of drinking water, swimming pool, hospital wastewater and water treatment engineering.

6814772a5d263414004dd4a4 Card 2

product image
Dissolved Chlorine

Online Dissolved Ozone Meter is used for continuous monitoring and controlling of ozone value in water treatment plants, canning plants, drinking water distribution networks, swimming pools, cooling and circulating water, water treatment projects, etc

6814772a5d263414004dd4a4 Card 2

product image
COD BOD

MicroSet launched the new generation COD BOD TSS TOC Sensor which is used for environmental protection purpose. Sensor is reagent free, pollution-free, more economic & robust. Due to small size, it is easier for installation for online continuous water quality monitoring. Sensor comes with Automatic compensation for turbidity interference, with automatic cleaning facility. For long-term monitoring it has excellent stability. Thanks to our R&D team for developing robust, trouble-free controller for processing the signals coming from the sensor. The Controller gives output of RS 485 MODBUS for real time data monitoring demands of SPCB & CPCB.

6814772a5d263414004dd4a4 Card 2

product image
TSS

The suspended solid sensor adopts infrared light technology for measurement. The instrument Analyse these data that are obtained by infrared light through the medium to the detector. It can know the exact concentration of suspended matter in the medium. It has the same accuracy and continuity when measuring low or high ranges. Besides, in order to effectively eliminate the deviation of data due to some changes of environment, so that it can be used in more environments. It is widely used in the monitoring of SS concentration in solution, such as Chemical, electroplating, paper making, ETP/STP/ WTP, Pharmaceutical, Food, water, etc.

6814772a5d263414004dd4a4 Card 2

product image
TSS

The suspended solid sensor adopts infrared light technology for measurement. The instrument analyze these data that are obtained by infrared light through the medium to the detector. It can know the exact concentration of suspended matter in the medium. It has the same accuracy and continuity when measuring low or high ranges. Besides, in order to effectively eliminate the deviation of data due to some changes of environment, so that it can be used in more environments. It is widely used in the monitoring of TSS, MLSS concentration in solution, such as Chemical, electroplating, papermaking, environmentally friendly water treatment engineering, pharmaceutical, food, tap water, etc.

6814772a5d263414004dd4a4 Card 2

product image
Turbidity

Turbidity is the degree of resistance that occurs when suspended solids in the water pass through light. The soil contains mud, silt, fine organic matter and other microorganisms and colloids to give turbidity in the water. After the light wave transmitted by the transmitter on the sensor is absorbed, reflected and scattered by the measured object during transmission, a part of the transmitted light can be irradiated onto the detector in the 180° direction, and a part of the scattered light is scattered to the detector in the 90° direction. The intensity of the light received on the detectors in the 180° and 90° directions is related to the turbidity of the measured sewage. Therefore, the turbidity of the sewage can be calculated by measuring the intensity of the transmitted and scattered light.

6814772a5d263414004dd4a4 Card 2

product image
Turbidity

Turbidity is the degree of resistance that occurs when suspended solids in the water pass through light. The soil contains mud, silt, fine organic matter and other microorganisms and colloids to give turbidity in the water. After the light wave transmitted by the transmitter on the sensor is absorbed, reflected and scattered by the measured object during transmission, a part of the transmitted light can be irradiated onto the detector in the 180° direction, and a part of the scattered light is scattered to the detector in the 90° direction. The intensity of the light received on the detectors in the 180° and 90° directions is related to the turbidity of the measured sewage. Therefore, the turbidity of the sewage can be calculated by measuring the intensity of the transmitted and scattered light.

6814772a5d263414004dd4a4 Card 2

product image
Flow

MS UFM 3111 Flow Meter can be virtually applied to a wide range of long term online measurement. Convertor protection Class IP 67, transducer protection class IP 68. A variety of liquid applications can be accommodated: ultra-pure liquids, portable water, chemicals, raw sewage, reclaimed water, cooling water, river water, plant effluent etc.

6814772a5d263414004dd4a4 Card 2

product image
Flow

MicroSet`s MS FL 0117 are micro-controller based full bore type electromagnetic flow meters specially used for various industrial applications. These flow meters accurately measure the flow rate of conductive liquids & slurries in closed pipes. Due to its simple & rigid design, the flow meter is an obstruction-less & maintenance-free instrument in place of conventional mechanical flow measuring devices. The use of 'pulsed DC' technology offers highest ability & better measuring accuracy in the form of electrical signal 4-20 mA DC linearly proportional to volumetric flow. The instrument is based on Faraday's law electromagnetic induction. A magnetic field is generated by the instrument in the flow tube. The fluid flowing though this magnetic field generates a voltage that is proportional to the flow velocity. Corresponding electrical output is provided with respect to measuring flow range

Subcategory Tags

Phone Number

Email Address team@microsetindia.com

Mon-Thu: 10 AM - 2 PM • Fri: 3 PM - 7AM

Address 102, Chinmay, 1103A 10, Lakaki Road, Model Colony, Shivajinagar