6814772a5d263414004dd4a4 Card 2

product image
Turbidity

Turbidity is the degree of resistance that occurs when suspended solids in the water pass through light. The soil contains mud, silt, fine organic matter and other microorganisms and colloids to give turbidity in the water. After the light wave transmitted by the transmitter on the sensor is absorbed, reflected and scattered by the measured object during transmission, a part of the transmitted light can be irradiated onto the detector in the 180° direction, and a part of the scattered light is scattered to the detector in the 90° direction. The intensity of the light received on the detectors in the 180° and 90° directions is related to the turbidity of the measured sewage. Therefore, the turbidity of the sewage can be calculated by measuring the intensity of the transmitted and scattered light.

6814772a5d263414004dd4a4 Card 2

product image
Turbidity

Turbidity is the degree of resistance that occurs when suspended solids in the water pass through light. The soil contains mud, silt, fine organic matter and other microorganisms and colloids to give turbidity in the water. After the light wave transmitted by the transmitter on the sensor is absorbed, reflected and scattered by the measured object during transmission, a part of the transmitted light can be irradiated onto the detector in the 180° direction, and a part of the scattered light is scattered to the detector in the 90° direction. The intensity of the light received on the detectors in the 180° and 90° directions is related to the turbidity of the measured sewage. Therefore, the turbidity of the sewage can be calculated by measuring the intensity of the transmitted and scattered light.

6814772a5d263414004dd4a4 Card 2

product image
TSS

The suspended solid sensor adopts infrared light technology for measurement. The instrument Analyse these data that are obtained by infrared light through the medium to the detector. It can know the exact concentration of suspended matter in the medium. It has the same accuracy and continuity when measuring low or high ranges. Besides, in order to effectively eliminate the deviation of data due to some changes of environment, so that it can be used in more environments. It is widely used in the monitoring of SS concentration in solution, such as Chemical, electroplating, paper making, ETP/STP/ WTP, Pharmaceutical, Food, water, etc.

6814772a5d263414004dd4a4 Card 2

product image
TSS

The suspended solid sensor adopts infrared light technology for measurement. The instrument analyze these data that are obtained by infrared light through the medium to the detector. It can know the exact concentration of suspended matter in the medium. It has the same accuracy and continuity when measuring low or high ranges. Besides, in order to effectively eliminate the deviation of data due to some changes of environment, so that it can be used in more environments. It is widely used in the monitoring of TSS, MLSS concentration in solution, such as Chemical, electroplating, papermaking, environmentally friendly water treatment engineering, pharmaceutical, food, tap water, etc.

6814772a5d263414004dd4a4 Card 2

product image
pH

FEATURE • Four Ceramic Junction → Fast Response due to increased porosity,Increased Sensor Life • Filled with Gel → Helps to maintain zero potential for longer time • Industrial Grade Rugged Construction • Easy Installation DESCRIPTION MicroSet make pH Sensor model MS pH 02 is designed for various Industrial Applications. Four ceramic junction reference aids in the sensor's resistance to harsh environments and helps prolong sensor life. The robust sensor design makes the MS pH 02 reliable in a wide range of aqueous solutions found in pipelines, open tanks or ponds. TECHNICAL SPECIFICATION Range : 0 to14 pH Body : Derlin Type : Combination Sensor Output : mV (± 59.4 mV/pH change at 25°C) Pressure : 6 Bar Temperature : 0 ~ 100°C Temperature Compensation : Pt 100 (Optional) Junction : Four Ceramic Process Connection : ¾” BSP Male on Front End and Rear End Mounting : Pipeline (Inline) or Immersion (Tank) or Flow Through Chamber Cable : Standard Integral Cable 5 Meter with BNC (Optional Leads) Cable Length: 10, 15, 20, 25 Meters Also Available (Optional At ExtraCost) Please specify Cable Length required while ordering Note: Integral Cable Cannot Be Extended from 5 Mtrs. to 10 Mtrs. or so

6814772a5d263414004dd4a4 Card 2

product image
pH

FEATURE • Four Ceramic Junction → Fast Response due to increased porosity, Increased Sensor Life • Filled with Gel → Helps to maintain zero potential for longer time • Industrial Grade Rugged Construction • Easy Installation DESCRIPTION MicroSet make pH Sensor model MS pH 03 is designed for various Industrial Applications. Four ceramic junction reference aids in the sensor's resistance to harsh environments and helps prolong sensor life. The robust sensor design makes the MS pH 03 reliable in a wide range of aqueous solutions found in pipelines, open tanks or ponds. TECHNICAL SPECIFICATION Range : 0~14 pH Sensor Output : mV (± 59.4 mV/pH change at 25°C) Body : Glass Type : Combination Junction : Four Ceramic Junction Pressure : 6 Bar Temperature : 0 ~100°C Shaft Length : 120 mm Shaft Diameter : 12 mm Membrane Resistance : 200 to 500 MΩ Temp. Compensation : Pt 100 (Optional) Process Connection : PG 13.5 Cable : Standard Integral 5 Meters with BNC (Optional Leads) Cable Length : 10, 15, 20, 25 Meters Also Available (Optional At Extra Cost) Please specify Cable Length required while ordering Note: Integral Cable Cannot Be Extended from 5 Mtrs. to 10 Mtrs. or so.

6814772a5d263414004dd4a4 Card 2

product image
pH

FEATURE • Four Ceramic Junction → Fast Response due to increased porosity, Increased Sensor Life • Filled with Gel → Helps to maintain zero potential for longer time • Industrial Grade Rugged Construction • Upto 130°C Operating Temperature • PTFE (Teflon) body for Harsh Application • Optionally Built in Temperature Compensation • Easy Installation DESCRIPTION MicroSet make pH Sensor model MS pH 04 is designed for various Industrial Applications. Four ceramic junction reference aids in the sensor's resistance to harsh environments and helps prolong sensor life. The robust sensor design makes the MS pH 04 reliable in a wide range of aqueous solutions found in pipelines, open tanks or ponds. TECHNICAL SPECIFICATION Range : 0 to14 pH Body MOC : PTFE Type : Combination Sensor Output : mV (± 59.4 mV/pH change at 25°C) Pressure : 6 Bar Temperature : 0 ~ 130°C Temperature Compensation : Pt 100 (Optional) Junction : Four Ceramic Process Connection : ¾” BSPM on Front End and Rear End Mounting : Pipeline (Inline) or Immersion (Tank) or Flow Through Chamber Cable : Standard Integral Cable 5 Meter with BNC (Optional Leads) Cable Length: 10, 15, 20, 25 Meters Also Available (Optional At Extra Cost) Please specify Cable Length required while ordering Note: Integral Cable Cannot Be Extended from 5 Mtrs. to 10 Mtrs. or so.

6814772a5d263414004dd4a4 Card 2

product image
pH

FEATURE • Sterilizable / Autoclavable • Gel electrolyte • Sterilization Temperature up to 130°C • 35 Steam Cycles - Ensures fast & accurate long life in actual process conditions • Fast, Accurate, Improved Stability, Reliable • 120, 170, 220, 270 and 320 mm Length available • Compatible with any make pH Transmitter DESCRIPTION Designed for accuracy and stability in a heat intensive application, the new MS pH 04 Ferm series pH sensors are optimized for autoclaving and steam sterilization in biotechnology applications. MS pH 04 sensors exhibit unparalleled stability after exposure to high temperature sterilization. The reference electrode uses a silver silver chloride sensor in combination with a new gelled potassium chloride electrolyte to provide a stable reference potential through the single ceramic reference junction. PRINCIPLE Why is pH Measurement required ? To check the acidic or alkaline nature of aqueous solution. pH (Potential Hydrogen) is unit of measurement, used to determine the Acidity or Alkalinity of an aqueous solution. Practical pH scale for industrial instrumentation ranges from 0 to 14 pH. The acidic substances range from 0 to 6 and on the other end are the alkaline substances, which range from 8 to 14, with pH 7 being neutral, this is the pH of pure water which is neither very acidic nor very alkaline, is said to be neutral. How is pH measured ? Although everyone is familiar with Litmus paper, the only reliable way to measure pH is using Potentiometric Combination electrodes. These electrodes develop a millivolts output corresponding to pH value of solution which is directly proportional to the Free Hydrogen ion concentration in an aqueous Solution. These generated raw mill volts are fed to MS pH 04 Ferm where it is processed by amplifier & reading is displayed on meter TECHNICAL SPECIFICATION pH Range : 0 ~ 14 pH Body : Glass Temperature Range : 0 to 130°C Operating Pressure : 6 Bar Electrolyte : Gel Reference Junction : Single Ceramic Junction Sterilization temperature : 130°C Shaft Length below Threads : 120 mm (Other Lengths on request at Extra Cost) Shaft Diameter : 12 mm Electrical Connection : S8 Process Connection : PG 13.5

6814772a5d263414004dd4a4 Card 2

product image
pH

FEATURE • Double junction • Filled with HGel+ gel suitable for demanding application • Industrial Grade Rugged Construction • Upto 140°C Operating Temperature • Upto 6 Bar @ 25°C • Suitable for Highly Acidic & Alkaline application • PTFE (Teflon) body for Harsh Application • Optionally Built in Temperature Compensation • Easy Installation DESCRIPTION MicroSet make pH Sensor model MS pH 21 is designed for various Industrial Applications. Double junction & HGel+ reference aids in the sensor's resistance to harsh environments helps prolong sensor life. The robust sensor design makes the MS pH 21 reliable in a wide range of aqueous solutions found in pipelines, open tanks, scrubbers or ponds. TECHNICAL SPECIFICATION Range : 0 to14 pH Body MOC : PTFE Type : Combination Sensor Output : mV (± 59.4 mV/pH change at 25°C) Pressure : 6 Bar @ 25°C Temperature : 0 ~ 140°C Temperature Compensation : Pt 100 (Optional) Shape of Membrane : Spherical, green glass Junction : double junction, Ceramic Reference Electrolyte : HGel+ Reference System : Ag/ Ag Wire (Double Junction) Process Connection : ¾” BSPM on Front End and Rear End Mounting : Pipeline (Inline) or Immersion (Tank) or Flow Through Chamber Cable : Standard Integral Cable 5 Meter with BNC (Optional Leads) Cable Length: 10, 15 Meters also available at extra cost Please specify Cable Length required while ordering Note: Integral Cable Cannot Be Extended from 5 Mtrs. to 10 Mtrs. or so.