Pune
08048046710
+919112455550

'hazard resistant orp measurement device'

Items tagged with 'hazard resistant orp measurement device'

6814772a5d263414004dd4a4 Card 2

product image
pH

FEATURE • Online Measurement • Auto / Manual Temp Compensation • 4-20 mA DC Output • On-Line Indication through LCD Display • Simple operating interface • 2 Wire System • Easy Installation DESCRIPTION MicroSet pH Indicating Transmitter Model MS pH 211 T is used for various industrial applications. MS pH 211 T is a convenient and cost-effective solution for monitoring and transmitting pH or ORP value. It can accept input from any pH or ORP sensor. MS pH 211 T output is in the form of Analogue 4-20 mA DC two wire

6814772a5d263414004dd4a4 Card 2

product image
pH

FEATURE • On-line measurement. 2 wire system. • 4-20 mA DC output. Auto/Manual temperature compensation. • On-Line indication through LCD display. • Simple operating interface with basic pictographs. • Easy installation with pre assembled empty enclosure & Plug in terminals. • Protection Class IP-66 • Software calibration with buffer solution MicroSet series MS pH 211T FLP are PH / ORP transmitters used for various industrial applications. It can accept input from pH / ORP electrode & pH / ORP signal is transmitted in the form of electrical 4 - 20 mA signal. The on-line pH / ORP indication is provided through LCD. Span / Zero adjustments are easily accessibly. These transmitters are suitable for any make of electrode.

6814772a5d263414004dd4a4 Card 2

product image
pH

FEATURE • Annular PTFE Junction → Fast Response • Due to increased porosity, Increased Sensor Life • Suitable for Viscous, Slurry Application • Easy cleaning • Filled with Gel → Helps to maintain • Zero potential for longer time • Industrial Grade Rugged Construction • Ryton Body (Acid Alkali Resistant) • Easy Installation DESCRIPTION MicroSet make pH Sensor model MS pH 36 is designed for various Industrial Applications. Annular PTFE junction reference aids in the sensor's resistance to harsh environments and helps prolong sensor life. The robust sensor design makes the MS pH 36 reliable in a wide range of aqueous solutions found in pipelines, open tanks or ponds. TECHNICAL SPECIFICATION Range : 0 to 14 pH Body : Ryton Type : Combination Reference Junction : TEFLON Membrane Shape : Rugged Electrode Tip with Semi dome Shape Electrolyte : Combination of HGEL +CEP + Polymer Gel Sensor Output : mV (± 59.4 mV/ORP change at 25°C) Response Time : 95% in 1 second Pressure : 100 PSIG Temperature : 0 ~ 105°C Temperature Compensation : Pt 100 Built-in Measurement Tip : Glass Junction : Double Junction Process Connection : ¾” NPT Male on both Front End and Rear End Mounting : Pipeline (Inline) or Immersion (Tank) or Flow Through Chamber

6814772a5d263414004dd4a4 Card 2

product image
pH

• Advanced Embedded Microcontroller Based Design • Can be connected to pH or ORP electrodes • Multivariable Display for Process Value, Relay Status, Temperature & 4 to 20 mA output • Easy Front Key Calibration • Auto / Manual Temperature Compensation • Set Point – 4 Nos • 3.2-inch LCD display • 4 to 20 mA DC Isolated Output for pH or ORP • Password can be Set • Weatherproof IP 66 Protection DESCRIPTION MicroSet pH ORP Indicating Controller Transmitter Model MS pH 97 is used for various industrial applications. MS pH 97 is a convenient and cost-effective solution for monitoring and maintaining pH or ORP value. It can accept input from any pH or ORP sensor. MS pH 97 output is in the form of Analogue 4-20 mA DC or MODBUS RS 485 RTU (Optional). Online pH ORP indication provided through LCD display is easily readable. 2 Nos Relay Outputs are provided to operate Alarm, Solenoid Valve, Pump etc. 4 Nos Setpoints for Relays can be programmed using Frontal Keypad

6814772a5d263414004dd4a4 Card 2

product image
ORP

MicroSet ORP Indicating Controller Transmitter Model MS OP 91 is used for various industrial applications. MS OP 91 is a convenient and cost effective solution for monitoring and maintaining ORP value. It can accept input from any ORP sensor. MS OP 91 output is in the form of Analogue 4-20 mA DC and Optionally MODBUS RS 485 RTU. Online ORP indication provided through LED is easily readable. 2 Nos Relay Outputs are provided to operate Alarm, Solenoid Valve, Pump etc. 4 Nos Setpoints for Relays can be programmed using Frontal Keypad.

6814772a5d263414004dd4a4 Card 2

product image
ORP

MicroSet make ORP Sensor model MS ORP 02 is designed for various Industrial Applications. Double ceramic junction reference aids in the sensor's resistance to harsh environments and helps prolong sensor life. The robust sensor design makes the MS ORP 02 reliable in a wide range of aqueous solutions found in pipelines, open tanks or ponds.

6814772a5d263414004dd4a4 Card 2

product image
ORP

MicroSet make ORP Sensor model MS ORP 03 is designed for various Industrial Applications. Double ceramic junction reference aids in the sensor's resistance to harsh environments and helps prolong sensor life. The robust sensor design makes the MS ORP 03 reliable in a wide range of aqueous solutions found in pipelines, open tanks or ponds.

6814772a5d263414004dd4a4 Card 2

product image
ORP

MicroSet make ORP Sensor model MS ORP 36 is designed for various Industrial Applications. Annular PTFE junction reference aids in the sensor's resistance to harsh environments and helps prolong sensor life. The robust sensor design makes the MS ORP 36 F reliable in a wide range of aqueous solutions found in pipelines, open tanks or ponds.

6814772a5d263414004dd4a4 Card 2

product image
pH

FEATURE • Sterilizable / Autoclavable • Gel electrolyte • Sterilization Temperature up to 130°C • 35 Steam Cycles - Ensures fast & accurate long life in actual process conditions • Fast, Accurate, Improved Stability, Reliable • 120, 170, 220, 270 and 320 mm Length available • Compatible with any make pH Transmitter DESCRIPTION Designed for accuracy and stability in a heat intensive application, the new MS pH 04 Ferm series pH sensors are optimized for autoclaving and steam sterilization in biotechnology applications. MS pH 04 sensors exhibit unparalleled stability after exposure to high temperature sterilization. The reference electrode uses a silver silver chloride sensor in combination with a new gelled potassium chloride electrolyte to provide a stable reference potential through the single ceramic reference junction. PRINCIPLE Why is pH Measurement required ? To check the acidic or alkaline nature of aqueous solution. pH (Potential Hydrogen) is unit of measurement, used to determine the Acidity or Alkalinity of an aqueous solution. Practical pH scale for industrial instrumentation ranges from 0 to 14 pH. The acidic substances range from 0 to 6 and on the other end are the alkaline substances, which range from 8 to 14, with pH 7 being neutral, this is the pH of pure water which is neither very acidic nor very alkaline, is said to be neutral. How is pH measured ? Although everyone is familiar with Litmus paper, the only reliable way to measure pH is using Potentiometric Combination electrodes. These electrodes develop a millivolts output corresponding to pH value of solution which is directly proportional to the Free Hydrogen ion concentration in an aqueous Solution. These generated raw mill volts are fed to MS pH 04 Ferm where it is processed by amplifier & reading is displayed on meter TECHNICAL SPECIFICATION pH Range : 0 ~ 14 pH Body : Glass Temperature Range : 0 to 130°C Operating Pressure : 6 Bar Electrolyte : Gel Reference Junction : Single Ceramic Junction Sterilization temperature : 130°C Shaft Length below Threads : 120 mm (Other Lengths on request at Extra Cost) Shaft Diameter : 12 mm Electrical Connection : S8 Process Connection : PG 13.5

Still searching for
hazard resistant orp measurement device?