Pune
08048046710
+919112455550

'fast installation conductivity transmitter'

Items tagged with 'fast installation conductivity transmitter'

6814772a5d263414004dd4a4 Card 2

product image
pH

FEATURE • Online Measurement • Auto / Manual Temp Compensation • 4-20 mA DC Output • On-Line Indication through LCD Display • Simple operating interface • 2 Wire System • Easy Installation DESCRIPTION MicroSet pH Indicating Transmitter Model MS pH 211 T is used for various industrial applications. MS pH 211 T is a convenient and cost-effective solution for monitoring and transmitting pH or ORP value. It can accept input from any pH or ORP sensor. MS pH 211 T output is in the form of Analogue 4-20 mA DC two wire

6814772a5d263414004dd4a4 Card 2

product image
pH

FEATURE • On-line measurement. 2 wire system. • 4-20 mA DC output. Auto/Manual temperature compensation. • On-Line indication through LCD display. • Simple operating interface with basic pictographs. • Easy installation with pre assembled empty enclosure & Plug in terminals. • Protection Class IP-66 • Software calibration with buffer solution MicroSet series MS pH 211T FLP are PH / ORP transmitters used for various industrial applications. It can accept input from pH / ORP electrode & pH / ORP signal is transmitted in the form of electrical 4 - 20 mA signal. The on-line pH / ORP indication is provided through LCD. Span / Zero adjustments are easily accessibly. These transmitters are suitable for any make of electrode.

6814772a5d263414004dd4a4 Card 2

product image
Conductivity

MicroSet’s Conductivity Sensors are designed for fast, easy & trouble free start up. These are ideal for measuring the concentration of dissolved solids in water. They are provided with an accurate predetermined factory calibration constant. Rugged design & corrosion resistant material keep electrode spacing & surface area constant. So cell constant remains stable for long period. Durability of material & high resistance to corrosion ensures the long life & require low maintenance.

6814772a5d263414004dd4a4 Card 2

product image
Conductivity

It is an economical meter for online measurement of specific Conductivity of solution using a Conductivity cell for RO plant or DM plant applications. It enables to measure the Conductivity without manual balancing and specific Conductivity is read directly on a digital panel. This is available in panel mounting facility in compact size. PRINCIPLE Conductivity is the ability of a solution, a metal or a gas - in brief all materials to pass an electric current. In solutions the current is carried by cations and anions whereas in metals it is carried by electrons. How well a solution conducts electricity depends on a number of factors: • Concentration of ions • Mobility of ions • Valence of ions • Temperature All substances possess some degree of conductivity. In aqueous solutions the level of ionic strength varies from the low conductivity of ultrapure water to the high conductivity of concentrated chemical samples. Conductivity may be measured by applying an alternating electrical current (I) to two electrodes immersed in a solution and measuring the resulting voltage (U). During this process, the cations migrate to the negative electrode, the anions to the positive electrode and the solution acts as an electrical conductor.

6814772a5d263414004dd4a4 Card 2

product image
Conductivity

It is an economical meter for online measurement of specific Conductivity of solution using a Conductivity cell for R.O plant or D.M plant applications. It enables to measure the Conductivity without manual balancing and specific Conductivity is read directly on a digital panel. This is available in panel mounting facility in compact size.

6814772a5d263414004dd4a4 Card 2

product image
pH

• Advanced Embedded Microcontroller Based Design • Can be connected to pH or ORP electrodes • Multivariable Display for Process Value, Relay Status, Temperature & 4 to 20 mA output • Easy Front Key Calibration • Auto / Manual Temperature Compensation • Set Point – 4 Nos • 3.2-inch LCD display • 4 to 20 mA DC Isolated Output for pH or ORP • Password can be Set • Weatherproof IP 66 Protection DESCRIPTION MicroSet pH ORP Indicating Controller Transmitter Model MS pH 97 is used for various industrial applications. MS pH 97 is a convenient and cost-effective solution for monitoring and maintaining pH or ORP value. It can accept input from any pH or ORP sensor. MS pH 97 output is in the form of Analogue 4-20 mA DC or MODBUS RS 485 RTU (Optional). Online pH ORP indication provided through LCD display is easily readable. 2 Nos Relay Outputs are provided to operate Alarm, Solenoid Valve, Pump etc. 4 Nos Setpoints for Relays can be programmed using Frontal Keypad

6814772a5d263414004dd4a4 Card 2

product image
pH

FEATURE • Advanced Embedded Microcontroller Based Design • IP 65 Weatherproof Enclosure • Easy Front Key Calibration • Auto / Manual Temperature Compensation • LED indication for relay status • Set Point – 4 Nos (Special Logic ) • 4 Digit, 1 inch High Intensity Red LED Display • pH Sensor Slope Indication (Health of pH Sensor) • 4 to 20 mA DC Isolated Output • RS 485 Isolated Output (Optional) DESCRIPTION MicroSet pH Indicating Controller Transmitter Model MS pH 97 is used for various industrial applications. MS pH 97 is a convenient and cost-effective solution for monitoring and maintaining pH value. It can accept input from any pH sensor. MS pH 97 output is in the form of Analogue 4-20 mA DC or MODBUS RS 485 RTU (Optional). Online pH indication provided through LED is easily readable. 2 Nos Relay Outputs are provided to operate Alarm, Solenoid Valve, Pump etc. 4 Nos Setpoints for Relays can be programmed using Frontal Keypad.

6814772a5d263414004dd4a4 Card 2

product image
pH

FEATURE • Four Ceramic Junction → Fast Response due to increased porosity,Increased Sensor Life • Filled with Gel → Helps to maintain zero potential for longer time • Industrial Grade Rugged Construction • Easy Installation DESCRIPTION MicroSet make pH Sensor model MS pH 02 is designed for various Industrial Applications. Four ceramic junction reference aids in the sensor's resistance to harsh environments and helps prolong sensor life. The robust sensor design makes the MS pH 02 reliable in a wide range of aqueous solutions found in pipelines, open tanks or ponds. TECHNICAL SPECIFICATION Range : 0 to14 pH Body : Derlin Type : Combination Sensor Output : mV (± 59.4 mV/pH change at 25°C) Pressure : 6 Bar Temperature : 0 ~ 100°C Temperature Compensation : Pt 100 (Optional) Junction : Four Ceramic Process Connection : ¾” BSP Male on Front End and Rear End Mounting : Pipeline (Inline) or Immersion (Tank) or Flow Through Chamber Cable : Standard Integral Cable 5 Meter with BNC (Optional Leads) Cable Length: 10, 15, 20, 25 Meters Also Available (Optional At ExtraCost) Please specify Cable Length required while ordering Note: Integral Cable Cannot Be Extended from 5 Mtrs. to 10 Mtrs. or so

6814772a5d263414004dd4a4 Card 2

product image
pH

FEATURE • Four Ceramic Junction → Fast Response due to increased porosity, Increased Sensor Life • Filled with Gel → Helps to maintain zero potential for longer time • Industrial Grade Rugged Construction • Easy Installation DESCRIPTION MicroSet make pH Sensor model MS pH 03 is designed for various Industrial Applications. Four ceramic junction reference aids in the sensor's resistance to harsh environments and helps prolong sensor life. The robust sensor design makes the MS pH 03 reliable in a wide range of aqueous solutions found in pipelines, open tanks or ponds. TECHNICAL SPECIFICATION Range : 0~14 pH Sensor Output : mV (± 59.4 mV/pH change at 25°C) Body : Glass Type : Combination Junction : Four Ceramic Junction Pressure : 6 Bar Temperature : 0 ~100°C Shaft Length : 120 mm Shaft Diameter : 12 mm Membrane Resistance : 200 to 500 MΩ Temp. Compensation : Pt 100 (Optional) Process Connection : PG 13.5 Cable : Standard Integral 5 Meters with BNC (Optional Leads) Cable Length : 10, 15, 20, 25 Meters Also Available (Optional At Extra Cost) Please specify Cable Length required while ordering Note: Integral Cable Cannot Be Extended from 5 Mtrs. to 10 Mtrs. or so.

Still searching for
fast installation conductivity transmitter?