'inline conductivity meter solution'

Items tagged with 'inline conductivity meter solution'

6814772a5d263414004dd4a4 Card 2

product image
Conductivity

It is an economical meter for online measurement of specific Conductivity of solution using a Conductivity cell for RO plant or DM plant applications. It enables to measure the Conductivity without manual balancing and specific Conductivity is read directly on a digital panel. This is available in panel mounting facility in compact size. PRINCIPLE Conductivity is the ability of a solution, a metal or a gas - in brief all materials to pass an electric current. In solutions the current is carried by cations and anions whereas in metals it is carried by electrons. How well a solution conducts electricity depends on a number of factors: • Concentration of ions • Mobility of ions • Valence of ions • Temperature All substances possess some degree of conductivity. In aqueous solutions the level of ionic strength varies from the low conductivity of ultrapure water to the high conductivity of concentrated chemical samples. Conductivity may be measured by applying an alternating electrical current (I) to two electrodes immersed in a solution and measuring the resulting voltage (U). During this process, the cations migrate to the negative electrode, the anions to the positive electrode and the solution acts as an electrical conductor.

6814772a5d263414004dd4a4 Card 2

product image
Conductivity

It is an economical meter for online measurement of specific Conductivity of solution using a Conductivity cell for R.O plant or D.M plant applications. It enables to measure the Conductivity without manual balancing and specific Conductivity is read directly on a digital panel. This is available in panel mounting facility in compact size.

6814772a5d263414004dd4a4 Card 2

product image
pH

FEATURE • Four Ceramic Junction → Fast Response due to increased porosity,Increased Sensor Life • Filled with Gel → Helps to maintain zero potential for longer time • Industrial Grade Rugged Construction • Easy Installation DESCRIPTION MicroSet make pH Sensor model MS pH 02 is designed for various Industrial Applications. Four ceramic junction reference aids in the sensor's resistance to harsh environments and helps prolong sensor life. The robust sensor design makes the MS pH 02 reliable in a wide range of aqueous solutions found in pipelines, open tanks or ponds. TECHNICAL SPECIFICATION Range : 0 to14 pH Body : Derlin Type : Combination Sensor Output : mV (± 59.4 mV/pH change at 25°C) Pressure : 6 Bar Temperature : 0 ~ 100°C Temperature Compensation : Pt 100 (Optional) Junction : Four Ceramic Process Connection : ¾” BSP Male on Front End and Rear End Mounting : Pipeline (Inline) or Immersion (Tank) or Flow Through Chamber Cable : Standard Integral Cable 5 Meter with BNC (Optional Leads) Cable Length: 10, 15, 20, 25 Meters Also Available (Optional At ExtraCost) Please specify Cable Length required while ordering Note: Integral Cable Cannot Be Extended from 5 Mtrs. to 10 Mtrs. or so

6814772a5d263414004dd4a4 Card 2

product image
pH

FEATURE • Four Ceramic Junction → Fast Response due to increased porosity, Increased Sensor Life • Filled with Gel → Helps to maintain zero potential for longer time • Industrial Grade Rugged Construction • Upto 130°C Operating Temperature • PTFE (Teflon) body for Harsh Application • Optionally Built in Temperature Compensation • Easy Installation DESCRIPTION MicroSet make pH Sensor model MS pH 04 is designed for various Industrial Applications. Four ceramic junction reference aids in the sensor's resistance to harsh environments and helps prolong sensor life. The robust sensor design makes the MS pH 04 reliable in a wide range of aqueous solutions found in pipelines, open tanks or ponds. TECHNICAL SPECIFICATION Range : 0 to14 pH Body MOC : PTFE Type : Combination Sensor Output : mV (± 59.4 mV/pH change at 25°C) Pressure : 6 Bar Temperature : 0 ~ 130°C Temperature Compensation : Pt 100 (Optional) Junction : Four Ceramic Process Connection : ¾” BSPM on Front End and Rear End Mounting : Pipeline (Inline) or Immersion (Tank) or Flow Through Chamber Cable : Standard Integral Cable 5 Meter with BNC (Optional Leads) Cable Length: 10, 15, 20, 25 Meters Also Available (Optional At Extra Cost) Please specify Cable Length required while ordering Note: Integral Cable Cannot Be Extended from 5 Mtrs. to 10 Mtrs. or so.

6814772a5d263414004dd4a4 Card 2

product image
pH

FEATURE • Double junction • Filled with HGel+ gel suitable for demanding application • Industrial Grade Rugged Construction • Upto 140°C Operating Temperature • Upto 6 Bar @ 25°C • Suitable for Highly Acidic & Alkaline application • PTFE (Teflon) body for Harsh Application • Optionally Built in Temperature Compensation • Easy Installation DESCRIPTION MicroSet make pH Sensor model MS pH 21 is designed for various Industrial Applications. Double junction & HGel+ reference aids in the sensor's resistance to harsh environments helps prolong sensor life. The robust sensor design makes the MS pH 21 reliable in a wide range of aqueous solutions found in pipelines, open tanks, scrubbers or ponds. TECHNICAL SPECIFICATION Range : 0 to14 pH Body MOC : PTFE Type : Combination Sensor Output : mV (± 59.4 mV/pH change at 25°C) Pressure : 6 Bar @ 25°C Temperature : 0 ~ 140°C Temperature Compensation : Pt 100 (Optional) Shape of Membrane : Spherical, green glass Junction : double junction, Ceramic Reference Electrolyte : HGel+ Reference System : Ag/ Ag Wire (Double Junction) Process Connection : ¾” BSPM on Front End and Rear End Mounting : Pipeline (Inline) or Immersion (Tank) or Flow Through Chamber Cable : Standard Integral Cable 5 Meter with BNC (Optional Leads) Cable Length: 10, 15 Meters also available at extra cost Please specify Cable Length required while ordering Note: Integral Cable Cannot Be Extended from 5 Mtrs. to 10 Mtrs. or so.

6814772a5d263414004dd4a4 Card 2

product image
Conductivity

Conductivity of water allows measuring ionic constituents of all types of water including surface water, process water in water supply and treatment plants. PRINCIPLE Conductivity is the ability of a solution, a metal, or a gas - in brief all materials to pass an electric current. In solutions the current is carried by cations and anions whereas in metals it is carried by electrons. How well a solution conducts electricity depends on a number of factors : • Concentration of ions • Mobility of ions • Valence of ions • Temperature All substances possess some degree of conductivity. In aqueous solutions, the level of ionic strength varies from the low conductivity of ultrapure water to the high conductivity of concentrated chemical samples. Conductivity may be measured by applying an alternating electrical current (I) to two Electrodes immersed in a solution and measuring the resulting voltage (U). During this process, the cations migrate to the negative Electrode, the anions to the positive electrode and the solution acts as an electrical conductor.

6814772a5d263414004dd4a4 Card 2

product image
TDS

Conductivity of water allows measuring ionic constituents of all types of water including surface water, process water in water supply and treatment plants. PRINCIPLE Conductivity is the ability of a solution, a metal, or a gas - in brief all materials to pass an electric current. In solutions the current is carried by cations and anions whereas in metals it is carried by electrons. How well a solution conducts electricity depends on a number of factors : • Concentration of ions • Mobility of ions • Valence of ions • Temperature All substances possess some degree of conductivity. In aqueous solutions, the level of ionic strength varies from the low conductivity of ultrapure water to the high conductivity of concentrated chemical samples. Conductivity may be measured by applying an alternating electrical current (I) to two Electrodes immersed in a solution and measuring the resulting voltage (U). During this process, the cations migrate to the negative Electrode, the anions to the positive electrode and the solution acts as an electrical conductor.

6814772a5d263414004dd4a4 Card 2

product image
TDS

Conductivity of water allows measuring ionic constituents of all types of water including surface waters, process waters in water supply and treatment plants. PRINCIPLE Conductivity is the ability of a solution, a metal or a gas - in brief all materials to pass an electric current. In solutions the current is carried by cations and anions whereas in metals it is carried by electrons. How well a solution conducts electricity depends on a number of factors • Concentration of ions • Mobility of ions • Valence of ions • Temperature All substances possess some degree of conductivity. In aqueous solutions the level of ionic strength varies from the low conductivity of ultrapure water to the high conductivity of concentrated chemical samples. Conductivity may be measured by applying an alternating electrical current (I) to two electrodes immersed in a solution and measuring the resulting voltage (U). During this process, the cations migrate to the negative Electrode, the anions to the positive electrode and the solution acts as an electrical conductor.

6814772a5d263414004dd4a4 Card 2

product image
pH

FEATURE • Four Ceramic Junction → Fast Response due to increased porosity, Increased Sensor Life • Filled with Gel → Helps to maintain zero potential for longer time • Industrial Grade Rugged Construction • Easy Installation DESCRIPTION MicroSet make pH Sensor model MS pH 03 is designed for various Industrial Applications. Four ceramic junction reference aids in the sensor's resistance to harsh environments and helps prolong sensor life. The robust sensor design makes the MS pH 03 reliable in a wide range of aqueous solutions found in pipelines, open tanks or ponds. TECHNICAL SPECIFICATION Range : 0~14 pH Sensor Output : mV (± 59.4 mV/pH change at 25°C) Body : Glass Type : Combination Junction : Four Ceramic Junction Pressure : 6 Bar Temperature : 0 ~100°C Shaft Length : 120 mm Shaft Diameter : 12 mm Membrane Resistance : 200 to 500 MΩ Temp. Compensation : Pt 100 (Optional) Process Connection : PG 13.5 Cable : Standard Integral 5 Meters with BNC (Optional Leads) Cable Length : 10, 15, 20, 25 Meters Also Available (Optional At Extra Cost) Please specify Cable Length required while ordering Note: Integral Cable Cannot Be Extended from 5 Mtrs. to 10 Mtrs. or so.