FEATURE • Four Ceramic Junction → Fast Response due to increased porosity, Increased Sensor Life • Filled with Gel → Helps to maintain zero potential for longer time • Industrial Grade Rugged Construction • Upto 130°C Operating Temperature • PTFE (Teflon) body for Harsh Application • Optionally Built in Temperature Compensation • Easy Installation DESCRIPTION MicroSet make pH Sensor model MS pH 04 is designed for various Industrial Applications. Four ceramic junction reference aids in the sensor's resistance to harsh environments and helps prolong sensor life. The robust sensor design makes the MS pH 04 reliable in a wide range of aqueous solutions found in pipelines, open tanks or ponds. TECHNICAL SPECIFICATION Range : 0 to14 pH Body MOC : PTFE Type : Combination Sensor Output : mV (± 59.4 mV/pH change at 25°C) Pressure : 6 Bar Temperature : 0 ~ 130°C Temperature Compensation : Pt 100 (Optional) Junction : Four Ceramic Process Connection : ¾” BSPM on Front End and Rear End Mounting : Pipeline (Inline) or Immersion (Tank) or Flow Through Chamber Cable : Standard Integral Cable 5 Meter with BNC (Optional Leads) Cable Length: 10, 15, 20, 25 Meters Also Available (Optional At Extra Cost) Please specify Cable Length required while ordering Note: Integral Cable Cannot Be Extended from 5 Mtrs. to 10 Mtrs. or so.

Keywords

Other Products

view all

6814772a5d263414004dd4a4 Card 2

product image
pH

• Advanced Embedded Microcontroller Based Design • Can be connected to pH or ORP electrodes • Multivariable Display for Process Value, Relay Status, Temperature & 4 to 20 mA output • Easy Front Key Calibration • Auto / Manual Temperature Compensation • Set Point – 4 Nos • 3.2-inch LCD display • 4 to 20 mA DC Isolated Output for pH or ORP • Password can be Set • Weatherproof IP 66 Protection DESCRIPTION MicroSet pH ORP Indicating Controller Transmitter Model MS pH 97 is used for various industrial applications. MS pH 97 is a convenient and cost-effective solution for monitoring and maintaining pH or ORP value. It can accept input from any pH or ORP sensor. MS pH 97 output is in the form of Analogue 4-20 mA DC or MODBUS RS 485 RTU (Optional). Online pH ORP indication provided through LCD display is easily readable. 2 Nos Relay Outputs are provided to operate Alarm, Solenoid Valve, Pump etc. 4 Nos Setpoints for Relays can be programmed using Frontal Keypad

6814772a5d263414004dd4a4 Card 2

product image
pH

FEATURE • Advanced Embedded Microcontroller Based Design • IP 65 Weatherproof Enclosure • Easy Front Key Calibration • Auto / Manual Temperature Compensation • LED indication for relay status • Set Point – 4 Nos (Special Logic ) • 4 Digit, 1 inch High Intensity Red LED Display • pH Sensor Slope Indication (Health of pH Sensor) • 4 to 20 mA DC Isolated Output • RS 485 Isolated Output (Optional) DESCRIPTION MicroSet pH Indicating Controller Transmitter Model MS pH 97 is used for various industrial applications. MS pH 97 is a convenient and cost-effective solution for monitoring and maintaining pH value. It can accept input from any pH sensor. MS pH 97 output is in the form of Analogue 4-20 mA DC or MODBUS RS 485 RTU (Optional). Online pH indication provided through LED is easily readable. 2 Nos Relay Outputs are provided to operate Alarm, Solenoid Valve, Pump etc. 4 Nos Setpoints for Relays can be programmed using Frontal Keypad.

6814772a5d263414004dd4a4 Card 2

product image
pH

FEATURE • Online Measurement • Auto / Manual Temp Compensation • 4-20 mA DC Output • On-Line Indication through LCD Display • Simple operating interface • 2 Wire System • Easy Installation DESCRIPTION MicroSet pH Indicating Transmitter Model MS pH 211 T is used for various industrial applications. MS pH 211 T is a convenient and cost-effective solution for monitoring and transmitting pH or ORP value. It can accept input from any pH or ORP sensor. MS pH 211 T output is in the form of Analogue 4-20 mA DC two wire