6814772a5d263414004dd4a4 Card 2

product image
Conductivity

It is an economical meter for online measurement of specific Conductivity of solution using a Conductivity cell for RO plant or DM plant applications. It enables to measure the Conductivity without manual balancing and specific Conductivity is read directly on a digital panel. This is available in panel mounting facility in compact size. PRINCIPLE Conductivity is the ability of a solution, a metal or a gas - in brief all materials to pass an electric current. In solutions the current is carried by cations and anions whereas in metals it is carried by electrons. How well a solution conducts electricity depends on a number of factors: • Concentration of ions • Mobility of ions • Valence of ions • Temperature All substances possess some degree of conductivity. In aqueous solutions the level of ionic strength varies from the low conductivity of ultrapure water to the high conductivity of concentrated chemical samples. Conductivity may be measured by applying an alternating electrical current (I) to two electrodes immersed in a solution and measuring the resulting voltage (U). During this process, the cations migrate to the negative electrode, the anions to the positive electrode and the solution acts as an electrical conductor.

6814772a5d263414004dd4a4 Card 2

product image
Conductivity

MicroSet’s Conductivity Sensors are designed for fast, easy & trouble free start up. These are ideal for measuring the concentration of dissolved solids in water. They are provided with an accurate predetermined factory calibration constant. Rugged design & corrosion resistant material keep electrode spacing & surface area constant. So cell constant remains stable for long period. Durability of material & high resistance to corrosion ensures the long life & require low maintenance.

6814772a5d263414004dd4a4 Card 2

product image
Conductivity

It is an economical meter for online measurement of specific Conductivity of solution using a Conductivity cell for R.O plant or D.M plant applications. It enables to measure the Conductivity without manual balancing and specific Conductivity is read directly on a digital panel. This is available in panel mounting facility in compact size.

6814772a5d263414004dd4a4 Card 2

product image
Dissolved Oxygen

MicroSet Dissolved Oxygen Indicating Controller Transmitter Model MS DO 27 is used for various industrial applications such as ETP, STP, WTP, Package drinking water, Power plant. MS DO 27 is a convenient and cost effective solution for monitoring and maintaining DO value. MS DO 27 accept input from any DO sensor in the form of milli Volts. MS DO 97 output is in the form of Analogue 4-20 mA DC or MODBUS RS 485 RTU (Optional). Online DO indication provided through 1” bright large LED which is easily readable, 2 Nos Relay Outputs are provided to operate Alarm, Solenoid Valve, Pump etc.4 Nos Setpoints for Relays can be programmed using Frontal Keypad.

6814772a5d263414004dd4a4 Card 2

product image
pH

• Advanced Embedded Microcontroller Based Design • Can be connected to pH or ORP electrodes • Multivariable Display for Process Value, Relay Status, Temperature & 4 to 20 mA output • Easy Front Key Calibration • Auto / Manual Temperature Compensation • Set Point – 4 Nos • 3.2-inch LCD display • 4 to 20 mA DC Isolated Output for pH or ORP • Password can be Set • Weatherproof IP 66 Protection DESCRIPTION MicroSet pH ORP Indicating Controller Transmitter Model MS pH 97 is used for various industrial applications. MS pH 97 is a convenient and cost-effective solution for monitoring and maintaining pH or ORP value. It can accept input from any pH or ORP sensor. MS pH 97 output is in the form of Analogue 4-20 mA DC or MODBUS RS 485 RTU (Optional). Online pH ORP indication provided through LCD display is easily readable. 2 Nos Relay Outputs are provided to operate Alarm, Solenoid Valve, Pump etc. 4 Nos Setpoints for Relays can be programmed using Frontal Keypad

6814772a5d263414004dd4a4 Card 2

product image
pH

FEATURE • Advanced Embedded Microcontroller Based Design • IP 65 Weatherproof Enclosure • Easy Front Key Calibration • Auto / Manual Temperature Compensation • LED indication for relay status • Set Point – 4 Nos (Special Logic ) • 4 Digit, 1 inch High Intensity Red LED Display • pH Sensor Slope Indication (Health of pH Sensor) • 4 to 20 mA DC Isolated Output • RS 485 Isolated Output (Optional) DESCRIPTION MicroSet pH Indicating Controller Transmitter Model MS pH 97 is used for various industrial applications. MS pH 97 is a convenient and cost-effective solution for monitoring and maintaining pH value. It can accept input from any pH sensor. MS pH 97 output is in the form of Analogue 4-20 mA DC or MODBUS RS 485 RTU (Optional). Online pH indication provided through LED is easily readable. 2 Nos Relay Outputs are provided to operate Alarm, Solenoid Valve, Pump etc. 4 Nos Setpoints for Relays can be programmed using Frontal Keypad.

6814772a5d263414004dd4a4 Card 2

product image
pH

FEATURE • Online Measurement • Auto / Manual Temp Compensation • 4-20 mA DC Output • On-Line Indication through LCD Display • Simple operating interface • 2 Wire System • Easy Installation DESCRIPTION MicroSet pH Indicating Transmitter Model MS pH 211 T is used for various industrial applications. MS pH 211 T is a convenient and cost-effective solution for monitoring and transmitting pH or ORP value. It can accept input from any pH or ORP sensor. MS pH 211 T output is in the form of Analogue 4-20 mA DC two wire

6814772a5d263414004dd4a4 Card 2

product image
pH

FEATURE • On-line measurement. 2 wire system. • 4-20 mA DC output. Auto/Manual temperature compensation. • On-Line indication through LCD display. • Simple operating interface with basic pictographs. • Easy installation with pre assembled empty enclosure & Plug in terminals. • Protection Class IP-66 • Software calibration with buffer solution MicroSet series MS pH 211T FLP are PH / ORP transmitters used for various industrial applications. It can accept input from pH / ORP electrode & pH / ORP signal is transmitted in the form of electrical 4 - 20 mA signal. The on-line pH / ORP indication is provided through LCD. Span / Zero adjustments are easily accessibly. These transmitters are suitable for any make of electrode.

6814772a5d263414004dd4a4 Card 2

product image
pH

FEATURE • Sterilizable / Autoclavable • Gel electrolyte • Sterilization Temperature up to 130°C • 35 Steam Cycles - Ensures fast & accurate long life in actual process conditions • Fast, Accurate, Improved Stability, Reliable • 120, 170, 220, 270 and 320 mm Length available • Compatible with any make pH Transmitter DESCRIPTION Designed for accuracy and stability in a heat intensive application, the new MS pH 04 Ferm series pH sensors are optimized for autoclaving and steam sterilization in biotechnology applications. MS pH 04 sensors exhibit unparalleled stability after exposure to high temperature sterilization. The reference electrode uses a silver silver chloride sensor in combination with a new gelled potassium chloride electrolyte to provide a stable reference potential through the single ceramic reference junction. PRINCIPLE Why is pH Measurement required ? To check the acidic or alkaline nature of aqueous solution. pH (Potential Hydrogen) is unit of measurement, used to determine the Acidity or Alkalinity of an aqueous solution. Practical pH scale for industrial instrumentation ranges from 0 to 14 pH. The acidic substances range from 0 to 6 and on the other end are the alkaline substances, which range from 8 to 14, with pH 7 being neutral, this is the pH of pure water which is neither very acidic nor very alkaline, is said to be neutral. How is pH measured ? Although everyone is familiar with Litmus paper, the only reliable way to measure pH is using Potentiometric Combination electrodes. These electrodes develop a millivolts output corresponding to pH value of solution which is directly proportional to the Free Hydrogen ion concentration in an aqueous Solution. These generated raw mill volts are fed to MS pH 04 Ferm where it is processed by amplifier & reading is displayed on meter TECHNICAL SPECIFICATION pH Range : 0 ~ 14 pH Body : Glass Temperature Range : 0 to 130°C Operating Pressure : 6 Bar Electrolyte : Gel Reference Junction : Single Ceramic Junction Sterilization temperature : 130°C Shaft Length below Threads : 120 mm (Other Lengths on request at Extra Cost) Shaft Diameter : 12 mm Electrical Connection : S8 Process Connection : PG 13.5