Ahmedabad
08048039609
+919112455550

'online chlorine control device'

Items tagged with 'online chlorine control device'

6814772a5d263414004dd4a4 Card 2

product image
pH

• Advanced Embedded Microcontroller Based Design • Can be connected to pH or ORP electrodes • Multivariable Display for Process Value, Relay Status, Temperature & 4 to 20 mA output • Easy Front Key Calibration • Auto / Manual Temperature Compensation • Set Point – 4 Nos • 3.2-inch LCD display • 4 to 20 mA DC Isolated Output for pH or ORP • Password can be Set • Weatherproof IP 66 Protection DESCRIPTION MicroSet pH ORP Indicating Controller Transmitter Model MS pH 97 is used for various industrial applications. MS pH 97 is a convenient and cost-effective solution for monitoring and maintaining pH or ORP value. It can accept input from any pH or ORP sensor. MS pH 97 output is in the form of Analogue 4-20 mA DC or MODBUS RS 485 RTU (Optional). Online pH ORP indication provided through LCD display is easily readable. 2 Nos Relay Outputs are provided to operate Alarm, Solenoid Valve, Pump etc. 4 Nos Setpoints for Relays can be programmed using Frontal Keypad

6814772a5d263414004dd4a4 Card 2

product image
pH

FEATURE • Advanced Embedded Microcontroller Based Design • IP 65 Weatherproof Enclosure • Easy Front Key Calibration • Auto / Manual Temperature Compensation • LED indication for relay status • Set Point – 4 Nos (Special Logic ) • 4 Digit, 1 inch High Intensity Red LED Display • pH Sensor Slope Indication (Health of pH Sensor) • 4 to 20 mA DC Isolated Output • RS 485 Isolated Output (Optional) DESCRIPTION MicroSet pH Indicating Controller Transmitter Model MS pH 97 is used for various industrial applications. MS pH 97 is a convenient and cost-effective solution for monitoring and maintaining pH value. It can accept input from any pH sensor. MS pH 97 output is in the form of Analogue 4-20 mA DC or MODBUS RS 485 RTU (Optional). Online pH indication provided through LED is easily readable. 2 Nos Relay Outputs are provided to operate Alarm, Solenoid Valve, Pump etc. 4 Nos Setpoints for Relays can be programmed using Frontal Keypad.

6814772a5d263414004dd4a4 Card 2

product image
ORP

MicroSet ORP Indicating Controller Transmitter Model MS OP 91 is used for various industrial applications. MS OP 91 is a convenient and cost effective solution for monitoring and maintaining ORP value. It can accept input from any ORP sensor. MS OP 91 output is in the form of Analogue 4-20 mA DC and Optionally MODBUS RS 485 RTU. Online ORP indication provided through LED is easily readable. 2 Nos Relay Outputs are provided to operate Alarm, Solenoid Valve, Pump etc. 4 Nos Setpoints for Relays can be programmed using Frontal Keypad.

6814772a5d263414004dd4a4 Card 2

product image
Dissolved Oxygen

MicroSet Dissolved Oxygen Indicating Controller Transmitter Model MS DO 27 is used for various industrial applications such as ETP, STP, WTP, Package drinking water, Power plant. MS DO 27 is a convenient and cost effective solution for monitoring and maintaining DO value. MS DO 27 accept input from any DO sensor in the form of milli Volts. MS DO 97 output is in the form of Analogue 4-20 mA DC or MODBUS RS 485 RTU (Optional). Online DO indication provided through 1” bright large LED which is easily readable, 2 Nos Relay Outputs are provided to operate Alarm, Solenoid Valve, Pump etc.4 Nos Setpoints for Relays can be programmed using Frontal Keypad.

6814772a5d263414004dd4a4 Card 2

product image
Dissolved Chlorine

Online Residual Dissolved Chlorine controller is widely used for the continuous monitoring and controlling of residual chlorine value in water solution, such as the automatic control of recirculating water, chlorination control in swimming pool, distribution network of drinking water, swimming pool, hospital wastewater and water treatment engineering.

6814772a5d263414004dd4a4 Card 2

product image
Conductivity

It is an economical meter for online measurement of specific Conductivity of solution using a Conductivity cell for R.O plant or D.M plant applications. It enables to measure the Conductivity without manual balancing and specific Conductivity is read directly on a digital panel. This is available in panel mounting facility in compact size.

6814772a5d263414004dd4a4 Card 2

product image
Dissolved Chlorine

Online Dissolved Ozone Meter is used for continuous monitoring and controlling of ozone value in water treatment plants, canning plants, drinking water distribution networks, swimming pools, cooling and circulating water, water treatment projects, etc

6814772a5d263414004dd4a4 Card 2

product image
pH

FEATURE • Online Measurement • Auto / Manual Temp Compensation • 4-20 mA DC Output • On-Line Indication through LCD Display • Simple operating interface • 2 Wire System • Easy Installation DESCRIPTION MicroSet pH Indicating Transmitter Model MS pH 211 T is used for various industrial applications. MS pH 211 T is a convenient and cost-effective solution for monitoring and transmitting pH or ORP value. It can accept input from any pH or ORP sensor. MS pH 211 T output is in the form of Analogue 4-20 mA DC two wire

6814772a5d263414004dd4a4 Card 2

product image
Conductivity

Conductivity of water allows measuring ionic constituents of all types of water including surface water, process water in water supply and treatment plants. PRINCIPLE Conductivity is the ability of a solution, a metal, or a gas - in brief all materials to pass an electric current. In solutions the current is carried by cations and anions whereas in metals it is carried by electrons. How well a solution conducts electricity depends on a number of factors : • Concentration of ions • Mobility of ions • Valence of ions • Temperature All substances possess some degree of conductivity. In aqueous solutions, the level of ionic strength varies from the low conductivity of ultrapure water to the high conductivity of concentrated chemical samples. Conductivity may be measured by applying an alternating electrical current (I) to two Electrodes immersed in a solution and measuring the resulting voltage (U). During this process, the cations migrate to the negative Electrode, the anions to the positive electrode and the solution acts as an electrical conductor.

Still searching for
online chlorine control device?