Ahmedabad
08048039609
+919112455550

'ip 66 protected ph orp sensor'

Items tagged with 'ip 66 protected ph orp sensor'

6814772a5d263414004dd4a4 Card 2

product image
pH

• Advanced Embedded Microcontroller Based Design • Can be connected to pH or ORP electrodes • Multivariable Display for Process Value, Relay Status, Temperature & 4 to 20 mA output • Easy Front Key Calibration • Auto / Manual Temperature Compensation • Set Point – 4 Nos • 3.2-inch LCD display • 4 to 20 mA DC Isolated Output for pH or ORP • Password can be Set • Weatherproof IP 66 Protection DESCRIPTION MicroSet pH ORP Indicating Controller Transmitter Model MS pH 97 is used for various industrial applications. MS pH 97 is a convenient and cost-effective solution for monitoring and maintaining pH or ORP value. It can accept input from any pH or ORP sensor. MS pH 97 output is in the form of Analogue 4-20 mA DC or MODBUS RS 485 RTU (Optional). Online pH ORP indication provided through LCD display is easily readable. 2 Nos Relay Outputs are provided to operate Alarm, Solenoid Valve, Pump etc. 4 Nos Setpoints for Relays can be programmed using Frontal Keypad

6814772a5d263414004dd4a4 Card 2

product image
pH

FEATURE • Online Measurement • Auto / Manual Temp Compensation • 4-20 mA DC Output • On-Line Indication through LCD Display • Simple operating interface • 2 Wire System • Easy Installation DESCRIPTION MicroSet pH Indicating Transmitter Model MS pH 211 T is used for various industrial applications. MS pH 211 T is a convenient and cost-effective solution for monitoring and transmitting pH or ORP value. It can accept input from any pH or ORP sensor. MS pH 211 T output is in the form of Analogue 4-20 mA DC two wire

6814772a5d263414004dd4a4 Card 2

product image
pH

FEATURE • On-line measurement. 2 wire system. • 4-20 mA DC output. Auto/Manual temperature compensation. • On-Line indication through LCD display. • Simple operating interface with basic pictographs. • Easy installation with pre assembled empty enclosure & Plug in terminals. • Protection Class IP-66 • Software calibration with buffer solution MicroSet series MS pH 211T FLP are PH / ORP transmitters used for various industrial applications. It can accept input from pH / ORP electrode & pH / ORP signal is transmitted in the form of electrical 4 - 20 mA signal. The on-line pH / ORP indication is provided through LCD. Span / Zero adjustments are easily accessibly. These transmitters are suitable for any make of electrode.

6814772a5d263414004dd4a4 Card 2

product image
pH

FEATURE • Annular PTFE Junction → Fast Response • Due to increased porosity, Increased Sensor Life • Suitable for Viscous, Slurry Application • Easy cleaning • Filled with Gel → Helps to maintain • Zero potential for longer time • Industrial Grade Rugged Construction • Ryton Body (Acid Alkali Resistant) • Easy Installation DESCRIPTION MicroSet make pH Sensor model MS pH 36 is designed for various Industrial Applications. Annular PTFE junction reference aids in the sensor's resistance to harsh environments and helps prolong sensor life. The robust sensor design makes the MS pH 36 reliable in a wide range of aqueous solutions found in pipelines, open tanks or ponds. TECHNICAL SPECIFICATION Range : 0 to 14 pH Body : Ryton Type : Combination Reference Junction : TEFLON Membrane Shape : Rugged Electrode Tip with Semi dome Shape Electrolyte : Combination of HGEL +CEP + Polymer Gel Sensor Output : mV (± 59.4 mV/ORP change at 25°C) Response Time : 95% in 1 second Pressure : 100 PSIG Temperature : 0 ~ 105°C Temperature Compensation : Pt 100 Built-in Measurement Tip : Glass Junction : Double Junction Process Connection : ¾” NPT Male on both Front End and Rear End Mounting : Pipeline (Inline) or Immersion (Tank) or Flow Through Chamber

6814772a5d263414004dd4a4 Card 2

product image
ORP

MicroSet make ORP Sensor model MS ORP 02 is designed for various Industrial Applications. Double ceramic junction reference aids in the sensor's resistance to harsh environments and helps prolong sensor life. The robust sensor design makes the MS ORP 02 reliable in a wide range of aqueous solutions found in pipelines, open tanks or ponds.

6814772a5d263414004dd4a4 Card 2

product image
ORP

MicroSet make ORP Sensor model MS ORP 03 is designed for various Industrial Applications. Double ceramic junction reference aids in the sensor's resistance to harsh environments and helps prolong sensor life. The robust sensor design makes the MS ORP 03 reliable in a wide range of aqueous solutions found in pipelines, open tanks or ponds.

6814772a5d263414004dd4a4 Card 2

product image
pH

FEATURE • Four Ceramic Junction → Fast Response due to increased porosity,Increased Sensor Life • Filled with Gel → Helps to maintain zero potential for longer time • Industrial Grade Rugged Construction • Easy Installation DESCRIPTION MicroSet make pH Sensor model MS pH 02 is designed for various Industrial Applications. Four ceramic junction reference aids in the sensor's resistance to harsh environments and helps prolong sensor life. The robust sensor design makes the MS pH 02 reliable in a wide range of aqueous solutions found in pipelines, open tanks or ponds. TECHNICAL SPECIFICATION Range : 0 to14 pH Body : Derlin Type : Combination Sensor Output : mV (± 59.4 mV/pH change at 25°C) Pressure : 6 Bar Temperature : 0 ~ 100°C Temperature Compensation : Pt 100 (Optional) Junction : Four Ceramic Process Connection : ¾” BSP Male on Front End and Rear End Mounting : Pipeline (Inline) or Immersion (Tank) or Flow Through Chamber Cable : Standard Integral Cable 5 Meter with BNC (Optional Leads) Cable Length: 10, 15, 20, 25 Meters Also Available (Optional At ExtraCost) Please specify Cable Length required while ordering Note: Integral Cable Cannot Be Extended from 5 Mtrs. to 10 Mtrs. or so

6814772a5d263414004dd4a4 Card 2

product image
pH

FEATURE • Four Ceramic Junction → Fast Response due to increased porosity, Increased Sensor Life • Filled with Gel → Helps to maintain zero potential for longer time • Industrial Grade Rugged Construction • Easy Installation DESCRIPTION MicroSet make pH Sensor model MS pH 03 is designed for various Industrial Applications. Four ceramic junction reference aids in the sensor's resistance to harsh environments and helps prolong sensor life. The robust sensor design makes the MS pH 03 reliable in a wide range of aqueous solutions found in pipelines, open tanks or ponds. TECHNICAL SPECIFICATION Range : 0~14 pH Sensor Output : mV (± 59.4 mV/pH change at 25°C) Body : Glass Type : Combination Junction : Four Ceramic Junction Pressure : 6 Bar Temperature : 0 ~100°C Shaft Length : 120 mm Shaft Diameter : 12 mm Membrane Resistance : 200 to 500 MΩ Temp. Compensation : Pt 100 (Optional) Process Connection : PG 13.5 Cable : Standard Integral 5 Meters with BNC (Optional Leads) Cable Length : 10, 15, 20, 25 Meters Also Available (Optional At Extra Cost) Please specify Cable Length required while ordering Note: Integral Cable Cannot Be Extended from 5 Mtrs. to 10 Mtrs. or so.

6814772a5d263414004dd4a4 Card 2

product image
pH

FEATURE • Four Ceramic Junction → Fast Response due to increased porosity, Increased Sensor Life • Filled with Gel → Helps to maintain zero potential for longer time • Industrial Grade Rugged Construction • Upto 130°C Operating Temperature • PTFE (Teflon) body for Harsh Application • Optionally Built in Temperature Compensation • Easy Installation DESCRIPTION MicroSet make pH Sensor model MS pH 04 is designed for various Industrial Applications. Four ceramic junction reference aids in the sensor's resistance to harsh environments and helps prolong sensor life. The robust sensor design makes the MS pH 04 reliable in a wide range of aqueous solutions found in pipelines, open tanks or ponds. TECHNICAL SPECIFICATION Range : 0 to14 pH Body MOC : PTFE Type : Combination Sensor Output : mV (± 59.4 mV/pH change at 25°C) Pressure : 6 Bar Temperature : 0 ~ 130°C Temperature Compensation : Pt 100 (Optional) Junction : Four Ceramic Process Connection : ¾” BSPM on Front End and Rear End Mounting : Pipeline (Inline) or Immersion (Tank) or Flow Through Chamber Cable : Standard Integral Cable 5 Meter with BNC (Optional Leads) Cable Length: 10, 15, 20, 25 Meters Also Available (Optional At Extra Cost) Please specify Cable Length required while ordering Note: Integral Cable Cannot Be Extended from 5 Mtrs. to 10 Mtrs. or so.

Still searching for
ip 66 protected ph orp sensor?